background image

Installation

3A6976C

7

4.

Assemble the sensor.

a.

Slip the o-ring (3) onto the sensor (1). See F

IG

3.

b.

Screw the sensor bushing (2) onto the sensor 

(1). See F

IG

. 3.

5.

Screw the sensor assembly into the pump. Use 
thread sealant as needed.

6.

Connect the sensors to your monitoring device 
according to your device’s instructions. See F

IG

. 4 

for sensor wiring connections. See Technical Data 
for electrical specifications.

Leak Sensor Kit 17Z666

1.

To install the sensors, first disconnect power to the 
control box. 

2.

Relieve pump pressure. Follow the Pressure Relief 
Procedure in your pump manual.

3.

Mount the leak detector control box in a convenient 
location. 

4.

Remove plugs from the pump air covers, if plugs are 
present. See F

IG

. 2.

5.

Screw the sensors into the pump. Use thread 
sealant, as needed. See F

IG

. 5. 

F

IG

. 3. ATEX-Certified Sensor Assembly

F

IG

. 4. Sensor Wiring Connections

1

2

3

Electric Shock

To avoid potential injury from electric shock, shut off 
power to the control box before installing the sensors 
or servicing the leak detector system.

Pressure Relief 

Your diaphragm pump stays pressurized until 
pressure is relieved manually. To help prevent 
serious injury from pressurized fluid, such as 
splashing in the eyes or on skin, follow the Pressure 
Relief Procedure when you stop pumping and before 
you install the leak detector sensors. Refer to your 
pump manual for the correct Pressure Relief 
Procedure. 

F

IG

. 5. Typical Control Box and Sensor Installation

Control Box

Sensors

Summary of Contents for 17Z666

Page 1: ...atmospheres or hazardous locations unless otherwise specified Part No 17Z666 Leak Sensor Kit Part No 17Z667 Leak Sensor Kit includes ATEX certified leak sensor Part No 25P303 Control Box Kit Part No 2...

Page 2: ...5 Grounding 5 Installation 6 ATEX Certified Leak Sensor Kit 17Z667 6 Leak Sensor Kit 17Z666 7 Connect Power to Control Box 9 Operation 9 Maintenance 9 Clean Sensors 9 Parts 10 Leak Sensor Kit 17Z666...

Page 3: ...prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static sp...

Page 4: ...reate safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route...

Page 5: ...ntification and Description Before you install the system you should be familiar with the parts discussed in the following paragraphs Sensors The sensors are mounted on the pump to detect liquid on th...

Page 6: ...to your monitoring device before installing the sensors or servicing the leak detector system Pressure Relief Your diaphragm pump stays pressurized until pressure is relieved manually To help prevent...

Page 7: ...location 4 Remove plugs from the pump air covers if plugs are present See FIG 2 5 Screw the sensors into the pump Use thread sealant as needed See FIG 5 FIG 3 ATEX Certified Sensor Assembly FIG 4 Sen...

Page 8: ...rminal strip CR1 9 Connect Sensor 2 to the control box by attaching the lead wires from the sensor to the sensor termi nals as follows a Attach the supply wire brown to either of the terminals marked...

Page 9: ...ox will be lit If an error or a diaphragm rupture or other leak occurs the green LED indicator corresponding to the sensor that identified the leak will extinguish The red FAULT LED indicator will lig...

Page 10: ...107186 PACKING O RING 2 This model is certified II 2 G Ex ib IIB T6 Gb Ref No Part No Description Qty 1 18A529 LEAK DETECTOR BOX 1 2 15G303 LABEL warning 1 Replacement warning labels signs tags and ca...

Page 11: ...00 psi 0 69 MPa 6 9 bar Maximum sensor operating temperature 257 F 125 C Rated operational voltage 4 5 15 4 VDC Leak Sensor Kit 17Z667 Maximum sensor pressure 125 psi 0 86 MPa 8 6 bar Maximum sensor o...

Page 12: ...inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation TH...