background image

Overview

3A6976C

5

Overview

Usage

The leak detection system monitors air operated double 
diaphragm pumps for diaphragm rupture or other leaks 
that may contaminate the fluid being pumped. The sys-
tem is made up of a main control box and two liquid 
detection sensors. The sensors are screwed into the air 
side of each diaphragm on the pump. Each sensor cor-
responds to a green LED indicator on the control box. 

When a sensor detects liquid, the corresponding green 
LED indicator will extinguish and the red FAULT LED 
indicator will light, indicating a diaphragm rupture or 
other leak has occurred. The control box also has the 
ability to control an external device such as an alarm, 
light, or air solenoid via an onboard relay.

During normal operation, the green LED indicators on 
the control box will remain lit. The red FAULT LED 
indicator will remain extinguished, indicating proper 
operation.

Component Identification and 
Description

Before you install the system, you should be familiar 
with the parts discussed in the following paragraphs.

Sensors

The sensors are mounted on the pump to detect liquid 
on the air side of each diaphragm. See F

IG

. 1 and F

IG

. 5.

NOTE: Leak sensor kit 17Z667 is ATEX certified and 
should not be used with control box kit 25P303. Control 
box kit 25P303 is not rated for use in hazardous 
locations. 

Control Box

The control box powers and continuously monitors the 
sensors. It will display a fault condition by lighting the 
red FAULT LED indicator when a diaphragm rupture or 
other leak is detected. The FAULT LED indicator will 
remain lit until the reset button is pressed.

Relay 

The relay has two sets of contacts that can be used to 
indicate an error by activating an output signal, such as 

turning off a valve, lighting a light, etc. The contacts are 
located on the CR3 terminal strip. See F

IG

. 6.

Grounding

Follow the instructions in your pump manual to ground 
the diaphragm pump system and check its electrical 
grounding continuity. 

The control box does not require electrical grounding.

Summary of Contents for 17Z666

Page 1: ...atmospheres or hazardous locations unless otherwise specified Part No 17Z666 Leak Sensor Kit Part No 17Z667 Leak Sensor Kit includes ATEX certified leak sensor Part No 25P303 Control Box Kit Part No 2...

Page 2: ...5 Grounding 5 Installation 6 ATEX Certified Leak Sensor Kit 17Z667 6 Leak Sensor Kit 17Z666 7 Connect Power to Control Box 9 Operation 9 Maintenance 9 Clean Sensors 9 Parts 10 Leak Sensor Kit 17Z666...

Page 3: ...prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static sp...

Page 4: ...reate safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route...

Page 5: ...ntification and Description Before you install the system you should be familiar with the parts discussed in the following paragraphs Sensors The sensors are mounted on the pump to detect liquid on th...

Page 6: ...to your monitoring device before installing the sensors or servicing the leak detector system Pressure Relief Your diaphragm pump stays pressurized until pressure is relieved manually To help prevent...

Page 7: ...location 4 Remove plugs from the pump air covers if plugs are present See FIG 2 5 Screw the sensors into the pump Use thread sealant as needed See FIG 5 FIG 3 ATEX Certified Sensor Assembly FIG 4 Sen...

Page 8: ...rminal strip CR1 9 Connect Sensor 2 to the control box by attaching the lead wires from the sensor to the sensor termi nals as follows a Attach the supply wire brown to either of the terminals marked...

Page 9: ...ox will be lit If an error or a diaphragm rupture or other leak occurs the green LED indicator corresponding to the sensor that identified the leak will extinguish The red FAULT LED indicator will lig...

Page 10: ...107186 PACKING O RING 2 This model is certified II 2 G Ex ib IIB T6 Gb Ref No Part No Description Qty 1 18A529 LEAK DETECTOR BOX 1 2 15G303 LABEL warning 1 Replacement warning labels signs tags and ca...

Page 11: ...00 psi 0 69 MPa 6 9 bar Maximum sensor operating temperature 257 F 125 C Rated operational voltage 4 5 15 4 VDC Leak Sensor Kit 17Z667 Maximum sensor pressure 125 psi 0 86 MPa 8 6 bar Maximum sensor o...

Page 12: ...inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation TH...