background image

Warnings

3A6976C

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The 
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. 
When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. 
Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this 
manual where applicable.

WARNING

ELECTRIC SHOCK HAZARD

Improper setup or usage of the system can cause electric shock.

Turn off and disconnect power cord before servicing equipment.

Do not expose to rain. Store indoors.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or 
solvent flowing through the equipment can cause static sparking. To help prevent fire and explosion:

Use equipment only in well-ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static sparking). 

Ground all equipment in the work area. See Grounding instructions.

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Use only grounded hoses.

Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until 
you identify and correct the problem.

Keep a working fire extinguisher in the work area.

Route exhaust away from all ignition sources. If diaphragm ruptures, fluid may be exhausted with air. 

FIRE AND EXPLOSION HAZARD

Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable 
vapors. To help prevent fire and explosion:

Clean plastic parts only in well-ventilated area.

Do not clean with a dry cloth.

Do not operate electrostatic guns in equipment work area.

Summary of Contents for 17Z666

Page 1: ...atmospheres or hazardous locations unless otherwise specified Part No 17Z666 Leak Sensor Kit Part No 17Z667 Leak Sensor Kit includes ATEX certified leak sensor Part No 25P303 Control Box Kit Part No 2...

Page 2: ...5 Grounding 5 Installation 6 ATEX Certified Leak Sensor Kit 17Z667 6 Leak Sensor Kit 17Z666 7 Connect Power to Control Box 9 Operation 9 Maintenance 9 Clean Sensors 9 Parts 10 Leak Sensor Kit 17Z666...

Page 3: ...prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static sp...

Page 4: ...reate safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route...

Page 5: ...ntification and Description Before you install the system you should be familiar with the parts discussed in the following paragraphs Sensors The sensors are mounted on the pump to detect liquid on th...

Page 6: ...to your monitoring device before installing the sensors or servicing the leak detector system Pressure Relief Your diaphragm pump stays pressurized until pressure is relieved manually To help prevent...

Page 7: ...location 4 Remove plugs from the pump air covers if plugs are present See FIG 2 5 Screw the sensors into the pump Use thread sealant as needed See FIG 5 FIG 3 ATEX Certified Sensor Assembly FIG 4 Sen...

Page 8: ...rminal strip CR1 9 Connect Sensor 2 to the control box by attaching the lead wires from the sensor to the sensor termi nals as follows a Attach the supply wire brown to either of the terminals marked...

Page 9: ...ox will be lit If an error or a diaphragm rupture or other leak occurs the green LED indicator corresponding to the sensor that identified the leak will extinguish The red FAULT LED indicator will lig...

Page 10: ...107186 PACKING O RING 2 This model is certified II 2 G Ex ib IIB T6 Gb Ref No Part No Description Qty 1 18A529 LEAK DETECTOR BOX 1 2 15G303 LABEL warning 1 Replacement warning labels signs tags and ca...

Page 11: ...00 psi 0 69 MPa 6 9 bar Maximum sensor operating temperature 257 F 125 C Rated operational voltage 4 5 15 4 VDC Leak Sensor Kit 17Z667 Maximum sensor pressure 125 psi 0 86 MPa 8 6 bar Maximum sensor o...

Page 12: ...inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation TH...

Reviews: