Modbus and I/O Data
312785B
27
NOTE: Shaded cells relate to the flow charts on pages 23-26.
Table 1: ProMix 2KS Digital Inputs (Modbus Register 40040)
Bit
Digital Input Binary
Name
Details
0:5
0 0 0 0 0 0 0 0 0 0 X X X X X X Recipe
Binary bits for viewing discrete inputs only.
6
0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Color Change
(CC)
Set bit to “1” to initiate Color Change (momentary)
7
0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Mix
Set bit initiate Mix mode (maintain)
8
0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 Purge
Set bit to “1” to initiate Purge sequence (maintained)
9
0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 Job_Complete Set bit to “1” to initiate Job Complete input (momen-
tary)
10
0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 External CC
Ready
Set bit to “1” to initiate External Color Change
(momentary)
11
0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 Not Used
12
0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 FC _Calibrate
Set bit to “1” to initiate a Flow Control Calibrate input
(momentary)
13
0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Gun_Trigger
Set bit to “1” to indicate the gun is actually triggered
(maintain while gun is triggered, remove when gun is
closed)
14
0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Reset_Alarm
Set bit to “1” to clear an active Alarm (momentary)
15
1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Remote Stop
Set bit to remotely stop unit (momentary)
Summary of Contents for 15V331