Modbus and I/O Data
28
312785B
NOTE: Shaded cells relate to the flow charts on pages 23-26.
Table 2: ProMix 2KS Digital Outputs (Modbus Register 40041)
Bit
Digital Input Binary
Name
Details
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Purge_CC_Active
“1” indicates Purge or Color Change is in prog-
ress
1
0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 Mix_Active
“1” indicates Mix is in progress
2
0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 Mix_Ready
“1” indicates No Alarms and OK to Mix
3
0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 CC_Fill_Active
“1” indicates the Fill portion of a Color Change is
in progress
4
0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 FCalActive
“1” indicates the Flow Control Calibrate routine is
in progress
5
0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 Flow_Rate_Alarm
“1” indicates the Flow Rate Alarm/Warning is
active
6
0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Special_1
“1” indicates the Special_1 output is on (monitor
only)
7
0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Special_2
“1” indicates the Special_2 output is on (monitor
only)
8
0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 Special_3
“1” indicates the Special_3 output is on (monitor
only)
9
0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 Special_4
“1” indicates the Special_4 output is on (monitor
only)
10
0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 Not Used
11
0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 Not Used
12
0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Alarm_General
“1” indicates a General Alarm is in process. (If
Mix_Active is still High, then a Warning only.) See
ProMix 2KS Active Alarms (Modbus Register
40010) on page 29 for details on type.
13
0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Alarm_Potlife
“1” indicates a Potlife Alarm is in process.
Summary of Contents for 15V331