Grace Industries, Inc.

2

TURN ON:

 Simultaneously pressing both side PWR buttons 

turns the SuperCELL® ON. 

TURN OFF:

 Simultaneously pressing and holding both side 

PWR buttons turns the SuperCELL® OFF. 

PAGE NAVIGATION:

 Pressing the MENU/PWR button cycles 

through the pages on the SuperCELL®. 

MOTION ALARM:

 If the SuperCELL® remains motionless 

for the preset length of time, the SuperCELL® will sound a 
repeating alarm tone and transmit man-down alarm 
messages. Motion Alarm can be enabled/disabled and 
the timing can be adjusted in the Setup Menu. To clear 
Alarm and reset the SuperCELL®, simultaneously press the 
MENU/PWR and SEL/PWR buttons. 

PANIC ALARM:

 Activate the Emergency Alarm by 

pressing and holding the # and * buttons for 3 seconds. 
When the countdown timer reaches zero, a Panic Alarm 
signal will be sent and ALARM will be displayed. To clear 
Alarm and reset the SuperCELL®, simultaneously press the 
MENU/PWR and SEL/PWR buttons. 

TOP BUTTON EVACUATION:

 To send a Global 

EVACUATION signal to compatible Grace Telemetry 
devices (in the same family of ID’s)

Press and hold top button for 3 seconds. When the timer 
reaches zero (0), and Evacuation Signal will be sent and 
||| EVAC ||| will be displayed. SuperCELL® will continue 
sending the Evacuation Signal until the unit is reset by 
simultaneously pressing MENU/PWR and SEL/PWR buttons. 

EVACUATION ACKNOWLEDGMENT:

 If an Evacuate message 

is received by the SuperCELL®, it can be manually 
acknowledged by simultaneously pressing the MENU/PWR 
and SEL/PWR buttons. 

ALARM MONITORING:

 Alerts the Incident Commander 

that a GRACE Man-Down telemetry device, within 
signaling range, is transmitting an alarm message. This alert 
can be cleared from SuperCELL® by  simultaneously press 
the MENU/PWR and SEL/PWR buttons.

NOTE:

 If an alarm has been received, SuperCELL® will not 

turn off  until the alarm has been cleared or reset. To force 
SuperCELL® to turn off  (even with an active alarm) hold down 
the 

Up

 button along with both side 

PWR

 buttons. 

SuperCELL® Display Icons

Quick-Start Guide

Always test SuperCELL® prior to use

Low Battery Indication / Battery Charging

When approximately 3 hours of operating time remain 

in standby mode, the SuperCELL® will display a plug icon 
on the display status screen. The power-on tones are not 
emitted when SuperCELL® has a low battery. Low battery is 
also indicated by the Operational Status LED changing to a 
periodic Red strobe. A double chirp sounds once every fi ve 
minutes with audio enabled. 

Warning: There are no audible 

low battery sounds with audio tones disabled.

When low battery is indicated, less than 3 hours of 

operating time remain and the battery should be charged 
immediately. 

With the charger provided, recharge time is approximately 

6 hours from a low battery warning and 9 hours for a 
dead battery. Due to current limits imposed by Intrinsic 
Safety requirements, a unit that has gone completely 
dead will have to be removed from the charging base and 
reinserted when the charging light turns Red. Typical 
operation time between recharging is approximately 40 
hours in standby/ready mode. 

Plug the charger into an outlet. It takes approximately 20 

seconds for the Green charger LED to light up. If it does not 
turn on or a Red LED turns on, then the battery is either too 
hot or cold, or has a fault. 

Charging is complete when the Green charge LED starts to 

slowly fl ash. 

120VAC Adapter

Optional 12VDC Adapter

Green 

Charge 

LED

Charging Base

Summary of Contents for SuperCELL SC500-H-IC

Page 1: ...own Alarm An optional safety monitoring feature which provides the Incident Commander with motion sensing protection Alarm Acknowledgment When a SuperCELL is in an alarm condition an Alarm Acknowledgm...

Page 2: ...s transmitting an alarm message This alert can be cleared from SuperCELL by simultaneously press the MENU PWR and SEL PWR buttons NOTE If an alarm has been received SuperCELL will not turn off until t...

Page 3: ...the stored alarm messages that were received by the SuperCELL The 32 most recent unique alarms are stored on the SuperCELL in the order they were received Turning the SuperCELL off clears the Alarm H...

Page 4: ...firmware version found on the device The Bottom text line displays the creation date of this firmware version Press the SEL PWR button to display the radio firmware version Pressing MENU PWR will navi...

Page 5: ...ELL enters alarm mode a pre alert warning tone will sound alerting the user that the device will enter alarm mode if it continues to remain motionless Upon entering Alarm Mode the SuperCELL will sound...

Page 6: ...able Constant Alarm Vibration proceed to the AlarmVibConstant page by pressing the MENU PWR button At the AlarmVibConstant page the SEL PWR button enables or disables the Constant Alarm Vibration sett...

Page 7: ...ph re dangereuse les batterie doivent tre charg es seulement dans une zone connu comme tre non dangereuse FCC Statements Changes or modifications not expressly approved by the party responsible for co...

Page 8: ...GRACE Industries telemetry device is placed in alarm mode by pressing the device s panic button When this occurs the device transmits an alarm signal and emits a loud alarm audio tone Canned Text Mes...

Reviews: