GPS1195 Auto Gate Manual                                                                          Version 3 

Terminal 9 – +24Vdc 

Terminal 10 – 24Vdc common 

Terminal 11 – 24Vdc common 

Terminal 12 – 24Vdc common 

 

Dip Switch Settings  

Switch 1 – On = Reset Loop Enabled 

Switch 1 – Off = Reset Loop Disabled 

Switch 2 – On = Free Loop Enabled 

Switch 2 – Off = Free Loop Disabled 

Switch 3 & 4 – 3 is Off, 4 is Off – Arming & Lockout 

Switch 3 is On, 4 is Off = Arming only 

 

 

 

 

 

                      

              

 

 

 

Page 8E 

Summary of Contents for GPS1195

Page 1: ...LOBAL PARKING SYSTEMS INC TEL 905 405 9800 FAX 905 405 9801 GPS1195 Automatic Barrier Gate INSTALLATION AND MAINTENANCE MANUAL E MAIL Info gpsgates com WEB SITE www gpsgates com DOCUMENT VERSION 4 201...

Page 2: ...id if any modifications changes or additions to the equipment are performed without written approval from Global Parking Systems In addition this warranty may be voided or further limited if the requi...

Page 3: ...e 5 Loop Detector Page 6 Loop Installation Page 7A 7B 7C PLC Version 2 Wiring Connections Page 8A 8B 8C 8D 8E Operating Instructions Page 9 Maintenance Page 10 Spring Adjustment Page 11 Power Failure...

Page 4: ...Connect each gate to a dedicated 15 AMP 120Vac circuit breaker Ensure the complete electrical installation is done according to all local Codes Regulations 8 The Gate shall be Powered and Protected t...

Page 5: ...and connect the 3 bolts supplied through the arm into the spacer and then the main shaft Never mount the spacer on the outside of the arm as you will damage the paint finish and the arm will become l...

Page 6: ...ay to provide smooth operation in both directions resulting in lower wear as well as reduced heat and power consumption Maximum run timers for both directions to prevent continuous cycling of barrier...

Page 7: ...plus all other forms of traffic like motorcycles RV s High bed trucks Trailers Construction vehicles etc The standard detector found in all GPS Equipment is the LMA 1250HV from EDI Failsafe 120vac 22...

Page 8: ...ield of the cable should be connected to earth ground at the detector only If splices are necessary connect as in 4 above and waterproof 6 All steel beams Iron drains Water pipes etc should be at leas...

Page 9: ...r Teflon are recommended No splices are to be made in the wire slots 5 Ensure the wires are not loose in the slot as this will cause future loop failure Do not use sharp tools or objects to push wires...

Page 10: ...e following formula can be used to calculate the approximate inductance of a loop N Number of Turns L N2 X 5 X 1 P Loop perimeter in feet 10 N L Loop inductance in microheneries Loop Area Square Feet...

Page 11: ...Green or Red Terminal 6 Traffic Light Red or Green Terminal 7 120Vac Line in Black Wire Terminal 8 120Vac Line in Black Wire Terminal 9 120Vac Neutral in White Wire Terminal 10 120V Neutral in White W...

Page 12: ...Terminal 15 Safety Edge Input Terminal 16 24V Input common Connector 3 Relay Contact Outputs Terminal 1 Lockout contact 1 Common Terminal 2 Lockout contact 1 Normally Closed Terminal 3 Lockout contact...

Page 13: ...rminal 3 Relay 3 Coil Terminal 4 Relay 4 sign relay Coil Terminal 5 Stop input Terminal 6 Relay 1 Contact 1 Normally Open Terminal 7 Relay 2 Contact 1 Normally Open Terminal 8 Relay 3 Contact 1 Normal...

Page 14: ...l 7 Relay 3 contact 2 Common Terminal 8 Relay 3 contact 2 Normally Closed Terminal 9 Relay 3 contact 2 Normally Open Terminal 10 Relay 4 contact 3 Common Terminal 11 Relay 4 contact 2 Normally Open Te...

Page 15: ...minal 11 24Vdc common Terminal 12 24Vdc common Dip Switch Settings Switch 1 On Reset Loop Enabled Switch 1 Off Reset Loop Disabled Switch 2 On Free Loop Enabled Switch 2 Off Free Loop Disabled Switch...

Page 16: ...Auto Manual switch to raise or lower the gate located to the side of the PLC board nearest the door opening 5 Observe the barrier arm position in up and down positions and adjust limit cams if necess...

Page 17: ...5W90 Synthetic Gear oil Check and tighten as required all nuts and bolts Check to insure the cabinet is securely mounted to the island Check that all wiring terminals connectors Etc are secure and are...

Page 18: ...turnbuckle loosen the 24mm nut at the top of the turnbuckle and then loosen the nut at the bottom of the turnbuckle The nut is left hand 4 Loosen the 24mm nut that secures the top of the connecting r...

Page 19: ...e may start automatically if it is left in the on position and could cause injury 1 Rotate the motor manually using the belt until the up limit cam makes contact with the limit switch 2 Leave the on o...

Page 20: ...am adjust forward or backwards cycle the gate once up and then down If the position of the gate arm is straight across the lane when closed retighten the down limit cam as much as possible so that no...

Page 21: ...position of the limit cams located on the main shaft inside the upper part of the gate The up limit switch is marked with a tag UP and the down limit switch is marked with a tag DOWN To adjust the lim...

Page 22: ...are lit up OOOO O O this way when the gate is down Outputs OOOOOOO O PR E S 0 1 2 3 Up Position When the vehicle moves onto the vend loop Input 0 and Output 1 turn on Inputs 0 1 2 3 4 5 input 3 goes...

Page 23: ...the up limit switch Auto Manual switch In Auto mode as the arm goes down output 0 lights up Inputs 0 1 2 3 4 5 Input 4 and 5 drop out When the down switch is made output OOOO O O 0 drops out and input...

Page 24: ...s the open button to raise the barrier input 6 lights once and Inputs 0 1 2 3 4 5 Output 1 lights once Both drop out once up limit switch is made Input 3 turns off as arm is going up O OOOO O Input 4...

Page 25: ...out and input 4 and 5 stay lit when the up switch is made When you release the latching keyswitch input 4 and 5 drop out Output 0 lights up and when the down switch is made output 0 drops out and inpu...

Page 26: ...ULLEY GPS 1195 2P 2 X 5 8 MOTOR PULLEY GPS 1195 5P 5 X REDUCER PULLEY GPS 1195 6P 6 X REDUCER PULLEY GPS 1195 FB2 2 HOLE FLANGE BEARING GPS 1195 RS RUBBER SEAL SET FOR MAINSHAFT BEARING GPS 1195 PSW P...

Page 27: ...D GPS 1195 33VB 4L 330V BELT GPS 1195 34VB 4L 340V BELT GPS 1195 UB 2X4 UTILITY POWER SWITCH BOX GPS 1195 UBC UTILITY BOX COVER GPS 1195 PDS POWER DISCONNECT SWITCH GPS 1195 55SPA 5 5MM SPRING ASSEMBL...

Page 28: ......

Reviews: