PCD Pump User Guide
Operations
2/20/19
GPD Global
®
8
Operations
Prior to operations, identify which model of PCD pump you will be using. Each PCD pump
model can be identified by the type of motor and feed way it uses; see details under
Pump
Identification
(pg 2).
1- Read Safety Notices
2- Initial Start Up
A- Disconnect Dispense Unit from Drive Unit
PCD3, PCD3L, PCD3H, PCD4, PCD4L, PCD4H, PCD4HB, PCD6, PCD6HB,
PCD7H
To disconnect the dispense and drive units from each other:
1. Loosen the two (2) set screws (Item 5).
2. Gently pull the drive unit (Item 3) away from the dispense unit (Item A).
IMPORTANT:
Prior to start up, read
Safety Notices
(pg iii) as this information must be read
and understood prior to using the pump!
CAUTION:
Do not switch on the dispense pump before medium has been fed into it. There is a
danger of damage to the pump if it is run dry. Even a brief period of dry run time can lead to the
destruction of the stator.
CAUTION:
Proceed carefully to avoid damage to the fit.