Maintenance
Magnetic systems attract Ferromagnetic particles. Regular cleaning is essential.
A clean magnet functions considerably better
All parts are best cleaned with pressurized air and/or a soft cloth. It’s also possible to deep clean with
special cleaning fluids that do not harm the material. Ensure that these fluids do not contaminate the
product
Regularly check that all warning pictograms and the identification plate are present at the correct locations
on the device. If warning pictograms or the identification plate should get lost or damaged, immediately
apply new ones to the original locations.
Always inform operating personnel regarding planned inspections, maintenance, repairs or if attending to
breakdowns.
Magnet bars
The low speed of the magnet bars and the relatively small amount of movements will cause only little wear
to the inner bars.
Normal wear can however always occur.
•
Depending on the product (abrasive or not) and the Fe contamination the magnet bar tubes can
wear out.
Wear as a following of abrasive product can be reduced by coating the outside bars, with for instance
tungsten carbide.
Please contact
GOUDSMIT magnetic systems BV
for advise.
•
After some time the pneumatic components inside the bars can wear out, so they need to be
replaced. The time interval for this is depending on the cleaning cycle, the product, etc. An indication
for revision is the air supply to the magnet.
When more than 8 bar is needed to move the magnet
bars, then the bar(s) need to be repaired/revised
= replacing the pneumatic components and