Vibrations
The magnet is to be protected against strong external vibrations, because the magnet might
lose
magnetic force permanently
and or the brittle ceramic magnet material might break.
The only vibrations caused by the clean flow magnet SECC are forced by the moving magnet bars. The
product channel in which it is placed has to be stiff enough to damp out the (relatively small) forces of
the moving magnet bars.
Cleaning
Minimum 2x per day
(more often when lots of Fe is in the product flow en less when proven possible)
cleaning (Fe disposal) of the device is advised for an optimal magnetic separation, and to prevent for Fe
accumulation on the magnet bar tubes and the problems that can be caused by that. Clean magnets
have the best Fe separation result. So, make sure to clean a little more than assumed necessary, to
achieve a satisfactory result of the clean flow magnet device.
For dirt cleaning: see chapter
Maintenance
Deliverable specials
Higher product temperatures
For high product temperatures there is the possibility of using other magnet material than the standard
Neoflux
®
magnets. See product specs in the appendices.
Abrasive products
If you have an abrasive product, we can supply the magnet bars and /or inside housing with a protective
coating, like for instance a tungsten carbide coating.
Use in FOOD product flows
The SECC can be adapted so that it can be used in your specific
food stream. It’s standard execution
already has little gaps or dead spots in the, already complete SS AISI304, product channel. The product
channel (or even complete h magnet bars) can be delivered in gap-free SS AISI304 or AISI316,
or in combination with other
– for instance prescribed or delivered by customer – food improved
materials. Surface treatments like electrolytic polishing, staining, etc. are naturally possible.
ATEX
IF components are built on or built in to the Atex approved magnetic device, by the customer or third
party, this can void Atex suitability.
It is the responsibility of the customer to take the right precautions for use in an Atex zone, like regular
cleaning to prevent for thick accumulating dust layers, and suitable grounding measures.
Read this manual thoroughly for all ATEX measures.
If you desire an ATEX declaration with the device, it has to be especially ordered. An additional