background image

Version 4.4 

– June 2018 

 

 
 
 

User Manual

 

 
 

Neoflux® auto-cleaning Cleanflow magnet, 

series SECC 

Automatic cleaning Fe separator by permanent magnetic force 

 

 

Suited

 for removal of ferromagnetic (like iron) parts out of powders and granulates. 

Not suited 

products that have a bad flowing capacity. 

 

 
 
 
 

 

 
 

The descriptions and pictures in this manual, used for explanation, may differ from your execution. 

We have enclosed the as-built drawing of the delivered article. 

 
 

 

 

GOUDSMIT Magnetic Systems B.V.

 

P.O. box 18 

5580 AA Waalre 

Petunialaan 19  

5582 HA Waalre 

The Netherlands 
 
Tel.:  

(+31) (0)40 221 32 83 

Internet: 

www.goudsmitmagnets.com

 

E-mail: 

[email protected]

 

 

Summary of Contents for Neoflux SECC Series

Page 1: ...d granulates Not suited products that have a bad flowing capacity The descriptions and pictures in this manual used for explanation may differ from your execution We have enclosed the as built drawing...

Page 2: ...asing of magnet bars added 2 2 01 2009 Chapter Troubleshooting changed to Malfunctions Service 3 0 08 2009 Specification sheet and declaration by the manufacturer separated from manual 3 1 04 2011 1 L...

Page 3: ...ystems B V All technical information contained in this manual together with any relevant drawings and technical descriptions we supply remain our property It may not be duplicated or disclosed without...

Page 4: ...ions Fout Bladwijzer niet gedefinieerd Danger of magnetic field Fout Bladwijzer niet gedefinieerd Danger of high voltage Fout Bladwijzer niet gedefinieerd Device description 13 Intended use user indic...

Page 5: ...he right to amend or modify the construction and or model of our products at any time whatsoever without any obligation to modify any previously supplied products accordingly Ferromagnetism The workin...

Page 6: ...s or non 100 exchangeable parts are used Lubrication products other than those prescribed are used The equipment is used injudiciously incorrectly negligently or not in accordance with its intent and...

Page 7: ...nd or mistaken delivery Identification plate On the device you will find an identification plate as pictured below Information on this plate is of great importance in case of service That is why we ad...

Page 8: ...1 2G inside device outside device h Type of Ex protection c constructional safety t protection by enclosure h non electrical equipment protection method not specified further T105 C Maximum surface te...

Page 9: ...plate only applies to the product produced by Goudsmit Magnetics The ATEX certified magnetic device requires additional purchase parts to be certified to the ATEX Directive This includes control unit...

Page 10: ...warning pictograms If the device remains easily accessible to persons then extra safety precautions e g fencing must be installed When safeguards are not possible make sure clear instructions are giv...

Page 11: ...person such as coins in your wallet or your keys Make use of non magnetic tools and workbenches fitted with a wooden worktop and preferably a non Fe frame for instance stainless steel Always be aware...

Page 12: ...ally connecting the device make sure the activities are performed by qualified personnel Switch off the electrical power supply before performing activities to the device Danger Risk of an electric sh...

Page 13: ...rt size Foreign part like other metals size that can cause damage to the magnet bar tubes have to be filtered out Mechanical or other sieving is advised Temperatures Suited for material stream tempera...

Page 14: ...temperatures there is the possibility of using other magnet material than the standard Neoflux magnets See product specs in the appendices Abrasive products If you have an abrasive product we can sup...

Page 15: ...to the Fe disposal chutes the magnets stay in the product channel In the Fe disposal chutes there are no magnets inside the tubes anymore so the Fe parts will no longer be magnetically attracted and t...

Page 16: ...purpose Every X hours cycle time depends on Fe contamination the magnet bar tubes have to be moved towards the left or right standard setting 4 hours The caught Fe parts will then be moved along with...

Page 17: ...n function Advantages automatic continuous Fe disposal During the Fe disposal cycle it is not needed to interrupt the product flow Because of this you can easily more often perform a Fe disposal cycle...

Page 18: ...ounted for the actuation of the magnet bar In each Fe outlet channel and sometimes in the product channel an inspection maintenance hatch is placed Through these one can check the magnet bar movements...

Page 19: ...noids for actuating the magnet bars 1 solenoid per layer are placed in or near the LOGO module on the control plate The air preparation unit is also placed on the control plate and exists of subsequen...

Page 20: ...use leakage of raw product Thereby ensure that the device is earthed Check that all the screw connections inside the device are secured against loosening Ensure that the channels are strong enough to...

Page 21: ...it passes the cleanflow Advise place a sieve filter in front of the SECC During maintenance or cleaning operation it is also advised to be very careful with the magnet bar tubes to avoid damage Drawin...

Page 22: ...that actuate the magnet bars Make sure that the air pressure to the solenoids continuously is max 6 bar Well functioning bars must move smoothly at 6 bar but they will not all move simultaneously bec...

Page 23: ...ed devices for the locally valid connected loads and ensure that the appropriate connection cables are designed for the electrical power to be drawn Ensure that all electrical connections are checked...

Page 24: ...onnecting the LOGO Electrical drawings see added diagrams drawings Connect 24 VDC on L and M to ground If you do not have 24VDC power supply available but you do have 120 230V 50 60Hz than you can use...

Page 25: ...the LOGO It is possible to adjust the parameters of the logic program in LOGO like the interval time between the Fe disposal movements of the magnet bars moving left right Changing the Fe disposal in...

Page 26: ...hange the value up down Then you can go to the next number and back with buttons and 5 Make steps 3 en 4 also for TL set to same value as TH 6 By pushing the OK button you confirm the changed values 7...

Page 27: ...nterval times can only be changed in the program inside the LOGO unit To save the adapted program to the eprom as well act as follows 1 Push the button Esc 2 walk to Stop with the arrows and push OK 3...

Page 28: ...he device or installation is placed and situated correctly all protective covers if applied have been fitted correctly that all foreign iron objects larger than 10mm are blocked from entering the prod...

Page 29: ...inform operating personnel regarding planned inspections maintenance repairs or if attending to breakdowns Magnet bars The low speed of the magnet bars and the relatively small amount of movements wi...

Page 30: ...way the protection plate at the head side of the device Then dismount the aluminium end flange of the magnet bar After that the pneumatic coupling at the other side of the housing needs to be dismount...

Page 31: ...t more frequently adjust cleaning cycle time parameters Not attracted objects are not magnetic Check if particles to be separated are magnetic using a permanent magnet Ferromagnetic parts close to the...

Page 32: ...f the drawing s added to this user manual in the added data sheet The spare parts are mostly wear parts such as magnet bars pneumatic parts inside the magnet bars the slide bushes or hutmanchets betwe...

Page 33: ...device in a dry safe place and to conserve fragile and or sensitive parts Dismantling scrapping On scrapping and or disposal of the device s parts separately take into account the different nature an...

Reviews: