![Gossen MetraWatt METRALINE PAT Operating Instructions Manual Download Page 23](http://html.mh-extra.com/html/gossen-metrawatt/metraline-pat/metraline-pat_operating-instructions-manual_2247297023.webp)
GMC-I Messtechnik GmbH
23
10.3.1 I
EA
– LN-PE
Not Applicable for PC II (without PE) and PC
III
Measurement is performed with the DUT in
the de-energized state.
The L and N terminals at the DUT are con-
nected to each other inside the test instru-
ment. An alternating voltage is applied
between L-N and PE and current is mea-
sured.
Connection
➭
Insert the test object’s mains plug into
the test socket.
Procedure
➭
Press the
I
EA
key.
➭
Select the “
LN-PE
” menu with the help of
the
scroll keys.
➭
Start the measurement by pressing the
OK
key.
➭
Review the default parameter for bal-
anced wiring (Yes/No), select it if neces-
sary using the
scroll keys and adjust
it to the momentary value using the
scroll keys.
Note!
If “Balanced Wiring: Yes” is selected,
the measured value is cut in half. This
is the case when the DUT includes Y
capacitors from L and N to PE.
➭
If the respective measured value is
smaller than the specified limit value,
OK
appears at the display and the
LED
lights up green.
➭
You can repeat the measurement by
pressing the
scroll key (reset), after
which the LED
goes out briefly until
the next measurement is performed.