28
GMC-I Messtechnik GmbH
Electrical Safety
Safety class
II per IEC 61010-1:2010/
EN 61010-1:2011/
VDE 0411-1:2011
Measurement category
50 V CAT I
Contamination degree
2
EX marking
CE 0080
II 2 G Ex ia IIA T4 Gb
Ex = prototype tested
II
= Device group
2
= Device category
G
= Atmosphere (gas)
Ex
= conforms to European
Ex standards
ia
= Type of protection
(intrinsic safety)
IIA = Explosion category
T4 = Temperature class
Gb = Equipment Protection
Level (EPL)
Tamb. = –10
°
C ... +50
°
C
(Tamb. = ambient temperature)
Prototype test certificate
INERIS 05ATEX0040
INERIS = Inspection and Certifi-
cation Authority
05 =
Year
ATEX =
Guideline
(Atmospheres Explosives)
0040 = Test Report No.
Serial number (fabrication number)
X Y 123456
X
= year of manufacture:
A
→
2016, B
→
2017 ...
Y
= month of manufacture
January A
February B
March C
April D
May E
June F
July G
August H
September I
October J
November K
December L
123456
= serial number
AG123456 means for example = device was built in July 2016