![GORMAN-RUPP PUMPS Super T6A60S-ZPP857-ESP Installation, Operation, And Maintenance Manual With Parts List Download Page 16](http://html1.mh-extra.com/html/gorman-rupp-pumps/super-t6a60s-zpp857-esp/super-t6a60s-zpp857-esp_installation-operation-and-maintenance-manual-with-parts-list_2246947016.webp)
OM-07174
SUPER T SERIES
PAGE B - 8
INSTALLATION
FLOW
DISCHARGE
LINE
SUCTION
LINE
SIGNAL CABLE
(ATTACH TO
SUCTION LINE)
SUBMERSIBLE
TRANSDUCER
(DOWNSTREAM
FROM SUCTION)
SUCTION
STRAINER
Figure 3. Typical Submersible Transducer Installation
DISCHARGE LINES
Siphoning
Do not terminate the discharge line at a level lower
than that of the liquid being pumped unless a
siphon breaker is used in the line. Otherwise, a si
phoning action causing damage to the pump
could result.
Valves
If a throttling valve is desired in the discharge line,
use a valve as large as the largest pipe to minimize
friction losses. Never install a throttling valve in a
suction line.
With high discharge heads, it is recommended that
a throttling valve and a system check valve be in
stalled in the discharge line to protect the pump
from excessive shock pressure and reverse rota
tion when it is stopped.
If the application involves a high discharge
head, gradually close the discharge throt
tling valve before stopping the pump.