INSTALLATION INSTRUCTIONS / REFRIGERANT PIPE CONNECTION
Drain joint installation
NOTE: The drain joint differ from appliance to appliance.
Fit the seal into the drain elbow, then insert
the drain joint into the base pan hole of
outdoor unit, rotate 90 to securely assemble
them. Connect the drain joint with an
extension drain hose (need to be purchased
separately), in case of the water draining off
the outdoor unit during the heating mode.
Refrigerant pipe connection
Refrigerant pipe connection
Preparation of the pipes
1. Flaring work
Main cause for refrigerant leakages due to
defect in the flaring work. Carry out correct
flaring work using the following procedure:
A:
Cut the pipes and the cable.
•
Use the piping kit accessory or pipes purchased locally.
•
Measure the distance between the indoor and the outdoor unit.
•
Cut the pipes a little longer than the measured distance.
•
Cut the cable 1.5 m longer than the pipe length.
B:
Burr removal
•
Completely remove all burrs from the cut cross section
of pipe/tube.
•
Put the end of the copper tube/pipe in a downward
direction as you remove burrs in order to avoid
dropping burrs into the tubing.
Picture 36
WARNING!
Maximum height and distances between
indoor and outdoor unit are limited!
Oil trap should be installed per 5-7 meters!
Picture 37
Picture 38
Model
Pipe dimensions
Gas
Liquid
KAS53ZM2DCINV
2*3/8’’
(
Ф
9.52)
2*1/4’’
(
Ф
6.35)
KAS105ZM4DCINV
4*3/8’’
(
Ф
9.52)
4*1/4’’
(
Ф
6.35)
Summary of Contents for KAT35MINV
Page 28: ...28 KOMBINACIJE...
Page 34: ...6 INSTALLATION INSTRUCTIONS Picture 3...
Page 56: ...28 COMBINATIONS...
Page 83: ...27 KOMBINACIJE...
Page 84: ...1 MINV...
Page 85: ...2 3 3 4 6 8 12 19 21 24 26 27 28 e 29...
Page 86: ...3 1 2 3 4 5 6 7 8 1 2 3...
Page 87: ...4 12 2 3 15 5 20 30 200 60 60 2 1...
Page 88: ...5 65 18 42 55 66...
Page 90: ...7 12 15 3 2 3 3...
Page 91: ...8 1 2 5 8 6 3 4 5...
Page 92: ...9 1 5 65 2 a 7 b 1 2 43 3 8 9 6...
Page 93: ...10 1 2 3 4 1 2 1 3 1 4 30 45 60 20 25 30 10 10 10 15 15 15 10 10 1 1 4 10 5 W 6 3 10 15 3 10...
Page 94: ...11 11 11...
Page 96: ...13 50 55 12 17 210 a 18 10 12 17 16 17 15...
Page 97: ...14 a 5 16 b c 2 a 21 b 30 22 18 19 21 22 e 23 f 23 23 20...
Page 98: ...15 c 5x16 23 d e 11 4 6 24 25 26 3 4 24 25 25 26...
Page 99: ...16 e 27 f 4 27 750 6 1 100 27 28 29...
Page 100: ...17 W 3 5 2 4 5 3 4 30 30 50 25 31...
Page 101: ...18 3 5 W 5 3 W 500 300 150 32 33...
Page 102: ...19 12 34...
Page 104: ...21 1 2 90 110 3 1 5 4 5 6 30 7 5 2 3 6 0 75 6 10 1 10 16 1 5 16 25 2 5...
Page 105: ...22 1 2 3 4 5 42 43 44...
Page 106: ...23 q 1 2 3 4 5 90 6 7 8 3 45 46...
Page 109: ...26 47 48 5...
Page 110: ...27 1 2 1 2 0 3 15 76 1x105 4 45 6 7 5 6 7 3 2 4 49...
Page 111: ...28 ON FF MODE COOL HEAT U FAN 17 MANUAL U COOL U COOL 30 50 52...
Page 112: ...29 e...