background image

SS-

CPC90-150

www.goodmanmfg.com

4/12

Supersedes 2/12

Standard Features

•  R-410A chlorine-free refrigerant
•  High-efficiency scroll compressors
•  Two-stage cooling
•  Copper tube / aluminum fin coils
•  Contactor with lugs
•  High- and low-pressure switches
•  High-capacity, steel-cased filter drier
•  Heater kits with single-point entry
•  24-volt terminal strip
•  Convertible
•  Easy to service
•  Built-in filter rack with standard 2” filters
•  Bottom utility entry
•  AHRI Certified; ETL Listed

Cabinet Features

•  Heavy-gauge, galvanized-steel cabinet with  

UV-resistant powder-paint finish

•  Full Perimeter Rail

up

 

to

 11.5 EER

C

ooling

 C

apaCity

:  90,000 — 146,000 Btu/

h

CpC C

ommERCial

7½- 

to

 12½-t

on

 t

hREE

-p

hasE

 

p

aCkagEd

 a

iR

 C

onditionERs

Contents

Nomenclature ........................................................................

2

Product Specifications ...........................................................

3

Airflow Data ...........................................................................

7

Heat Kit Electrical Data  .......................................................

11

Expanded Cooling Data .......................................................

16

Dimensions ..........................................................................

26

Wiring Diagrams  .................................................................

30

Accessories ...........................................................................

34

*  Complete warranty details available from your local dealer or at www.goodmanmfg.com.

Summary of Contents for CPC CONVERCIAL SS-CPC90-150

Page 1: ...lt in filter rack with standard 2 filters Bottom utility entry AHRI Certified ETL Listed Cabinet Features Heavy gauge galvanized steel cabinet with UV resistant powder paint finish Full Perimeter Rail...

Page 2: ...led Op7ons 400 400 000 BTU h 025 25 kW 075 75 kW X No OpBons A Down ow Economizer Voltage Supply Fan Drive Type Motors 1 208 230 1 60 4 460 3 60 B Belt Drive 3 208 230 3 60 7 575 3 60 D Direct Drive H...

Page 3: ...AX51 AX51 AX51 Condenser Fan Coil Quantity of Condenser Fan Motors 2 2 2 Horsepower RPM 1075 890 1 075 Fan Diameter Fan Blades 22 4 22 4 22 4 Outdoor Nominal CFM 7 200 7 200 7 200 Face Area ft 36 36...

Page 4: ...AX51 AX51 AX51 Condenser Fan Coil Quantity of Condenser Fan Motors 2 2 2 Horsepower RPM 1 4 1 090 1 4 890 1 4 1 075 Fan Diameter Fan Blades 22 4 22 4 22 4 Outdoor Nominal CFM 7 200 7 200 7 200 Face A...

Page 5: ...AX51 Condenser Fan Coil Quantity of Condenser Fan Motors 2 2 2 Horsepower RPM 1 075 1 075 1 075 Fan Diameter Fan Blades 22 3 22 3 22 3 Outdoor Nominal CFM 8 200 8 200 8 200 Face Area ft 32 4 32 4 32 4...

Page 6: ...3 22 3 Outdoor Nominal CFM 8 400 8 400 8 400 Face Area ft2 35 3 35 3 35 3 Rows Deep Fins per Inch 2 3 rows 15 fpi 2 3 rows 15 fpi 2 3 rows 15 fpi Belt Drive Evap Fan Data of Wheels D x W 1 15 x 15 1 1...

Page 7: ...dard Belt Drive Horizontal ESP W C Turns Open 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 1 3625 701 1 08 3309 660 0 86 0 3 3815 797 1 44 3468 747 1 11 3177 7...

Page 8: ...Belt Drive Horizontal ESP W C Turns Open 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 1 3475 698 1 05 3159 657 0 83 0 3 3665 794 1 41 3318 744 1 08 3027 700 0...

Page 9: ...elt Drive Horizontal ESP W C Turns Open 0 1 2 3 4 5 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0 2 4562 736 1 58 4253 691 1 29 3893 642 1 0 4 4497 780 1 7 4200 736 1 41 37...

Page 10: ...izontal ESP W C Turns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0 2 5570 2 27 4935 1 70 4584 1 36 0 4 5871 3 20 5639 2 77 5307 2 31 4902 1 88 4637 1 55 4178 1 19 0 6 5610 3 00 5...

Page 11: ...sage MCA at 575V MOP amps at 575V Actual kW at 575V Recommended Airflow Range CPC090 7B 13 15 EHK7 16 22 25 15 3000 3375 CFM EHK7 30 41 45 30 3000 3375 CFM EHK7 45 57 60 43 3000 3375 CFM Minimum Circu...

Page 12: ...45 70 70 43 3400 3825 CFM 3400 3825 CFM Model and Heat Kit Usage MCA at 575V MOP amps at 575V Actual kW at 575V Recommended Airflow Range Downshot Recommended Airflow Range Horizontal CPC102 7B 17 20...

Page 13: ...000 4500 CFM Model and Heat Kit Usage MCA at 480V MOP amps at 480V Actual kW at 480V Recommended Airflow Range CPC120 4B 24 30 EHK4 16 27 30 15 3500 4500 CFM EHK4 30 50 50 30 3500 4500 CFM EHK4 45 70...

Page 14: ...600 Model and Heat Kit Usage MCA at 575V MOP amps at 575V Actual kW at 575V Recommended Airflow Range CPC150 7B 23 30 EHK7 16 24 30 15 4000 5600 EHK7 30 43 45 30 4300 5600 EHK7 45 59 60 43 4500 5600 M...

Page 15: ...85 0 76 0 58 0 37 0 87 0 78 0 59 0 38 0 90 0 81 0 61 0 39 0 94 0 84 0 63 0 41 0 94 0 84 0 64 0 41 T 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10 kW 6 31 6 43 6 61 6 80 6 74...

Page 16: ...6 444 414 445 470 490 Lo PR 101 108 118 125 107 114 124 132 111 118 129 138 117 124 136 145 123 130 142 152 127 135 147 157 85 3375 MBh 90 8 92 6 97 0 103 4 88 7 90 4 94 7 101 0 86 6 88 3 92 4 98 6 84...

Page 17: ...07 4 83 2 85 7 92 7 99 5 S T 0 79 0 71 0 53 0 34 0 82 0 73 0 55 0 36 0 84 0 75 0 57 0 37 0 87 0 77 0 59 0 38 0 90 0 80 0 61 0 39 0 91 0 81 0 61 0 39 T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 2...

Page 18: ...5 464 433 466 492 513 LO PR 102 108 118 126 107 114 125 133 111 119 129 138 117 125 136 145 123 131 143 152 127 135 147 157 85 3600 MBh 105 3 107 3 112 4 119 9 102 8 104 8 109 8 117 1 100 4 102 3 107...

Page 19: ...134 1 109 4 112 6 121 9 130 8 103 9 107 0 115 8 124 3 96 3 99 1 107 3 115 1 S T 0 84 0 76 0 57 0 37 0 88 0 78 0 59 0 38 0 90 0 80 0 61 0 39 0 93 0 83 0 63 0 40 0 96 0 86 0 65 0 42 0 97 0 87 0 66 0 42...

Page 20: ...9 468 437 470 496 517 Lo Pr 104 111 121 129 110 117 128 136 114 122 133 142 120 128 140 149 126 134 146 156 130 139 151 161 85 4500 MBh 121 8 124 1 130 0 138 7 118 9 121 2 127 0 135 5 116 1 118 4 124...

Page 21: ...0 56 0 36 0 85 0 76 0 57 0 37 0 88 0 78 0 59 0 38 0 91 0 81 0 62 0 40 0 92 0 82 0 62 0 40 T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11 kW 10 50 10 72 11 06 11 41 11 31 11...

Page 22: ...0 497 518 Lo PR 98 105 114 122 104 111 121 129 108 115 126 134 114 121 132 140 119 127 138 147 123 131 143 152 85 4725 MBh 150 7 153 6 160 9 171 6 147 2 150 0 157 1 167 6 143 7 146 4 153 4 163 6 140 2...

Page 23: ...TURN SUPPLY 5 3 8 7 1 2 6 1 2 99 1 8 61 3 4 Y NOTE For horizontal discharge remove the supply and return duct covers and place them over the vertical discharge return and supply openings Install with...

Page 24: ...roper unit operation Leave a total clearance of 75 on the main control panel side of the unit for possible removal of fan shaft coil electric heat and gas furnace Leave a clearance of 48 on all other...

Page 25: ...rtant If using bottom discharge with roof curb duct work should be attached to the curb prior to installing the unit Duct work dimensions are shown in Roof Curb Installation Instructions Manual Refer...

Page 26: ...ocating and mounting the curb and package unit Duct work must be constructed using industry guidelines The duct work must be placed into the roof curb before mounting the package unit Our full perimet...

Page 27: ...s 0907 and below Wiring is subject to change Always refer to the wiring diagram or the unit for the most up to date wiring W arning High Voltage Disconnect all power before servicing or installing thi...

Page 28: ...bers 0907 and below Wiring is subject to change Always refer to the wiring diagram or the unit for the most up to date wiring Warning High Voltage Disconnect all power before servicing or installing t...

Page 29: ...K OR BK RD 0140L00548 REV B BL RD RD COMP1 T2 T3 T1 YL BK RD LPS1 HPS1 BL PK BL 208 240 BL BL YL LPS2 OR O TB1 C PU BL YL GR WH Y1 RD BR Y Y2 S M E W1 A R G T T W2 R O T H 6 2 WH 8 5 7 BL PLF 1 3 9 4...

Page 30: ...BTION BLOCK FEMALE PLUG CONNECTOR REVERSING VAVLE COIL RUN CAPACITOR FOR COMPRESSOR AND FAN TERMINAL BLOCK 24V SIGNAL TRANSFORMER TR 4 OF OVER CURRENT PROTECTION 5 SEE UNIT RATING PLATE FOR TYPE AND S...

Page 31: ...er 7 10 tons DNECONGS150 Downflow Economizer 12 tons DNSQRRND90 Downflow Square to Round Adapter 20 Round 7 tons Electric Heat Kits HSKT090 High Static Kit for 7 ton CPC AA 8 ton CPCAA 230 460v 7 8 to...

Page 32: ...C90 150 Goodman Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2012 Goodman Manufacturing C...

Reviews: