5
B10259-216
CO can cause serious illness including permanent brain
damage or death.
Advertencia especial para la instalación de calentadores ó manejadoras
de aire en áreas cerradas como estacionamientos ó cuartos de servicio.
B10259-216
El monóxido de carbono puede causar enfermedades severas
como daño cerebral permanente ó muerte.
Las emisiones de monóxido de carbono pueden circular a través
del aparato cuando se opera en cualquier modo.
B10259-216
RISQUE D'EMPOISONNEMENT AU MONOXYDE DE CARBONE
Le monoxyde de
des
carbone peut causer des maladies graves telles que
dommages permanents au cerveau et meme la mort.
Cette ventilation est nécessaire pour éviter le danger d'intoxication
au CO pouvant survenir si un appareil produisant du monoxyde
de carbone continue de fonctionner au sein de la zone confinée.
ORDERING PARTS
When reporting shortages or damages, or ordering repair
parts, give the complete model and serial numbers as
stamped on the units nameplate. Replacement parts for
this appliance are available through your contractor or
local distributor. For the location of your nearest distributor,
consult the white business pages, the yellow page section
of the local telephone book or contact:
HOMEOWNER SUPPORT
Goodman Manufacturing Company, L.P.
19001 KERMIER ROAD
Houston, Texas 77484
877-254-4729
GENERAL INFORMATION
This unit is approved for outdoor installation ONLY.
To
assure that your unit operates safely and efficiently, it
must be installed, operated, and maintained in accordance
with these installation and operating instructions, all local
building codes and ordinances, or in their absence, with the
latest edition of the National Fuel Gas Code NFPA 54/ANSI
Z223.1 and National Standard of Canada CAN/CSA B149
Installation Codes.
The heating and cooling capacities of the unit should be
greater than or equal to the design heating and cooling
loads of the area to be conditioned. The loads should
be calculated by an approved method or in accordance
with A.S.H.R.A.E. Guide or Manual J - Load Calculations
published by the Air Conditioning Contractors of America.
Obtain from:
American National Standards Institute
25 West 43rd street, 4th Floor
New York, NY 10036
PRE-INSTALLATION CHECKS
Before attempting any installation, the following points
should be considered:
• Structural strength of supporting members
• Clearances and provision for servicing
• Power supply and wiring
• Air duct connections
• Drain facilities and connections
• Gas piping and connections
• Location may be on any four sides of a home,
manufactured or modular, to minimize noise
UNIT INSTALLATION
WARNING
To prevent possible equipment damage, property
damage, personal injury or death, the following
bullet points must be observed when installing the
unit
Summary of Contents for APD 14 M Series
Page 23: ...23 UNIT DIMENSIONS...