Good Earth Lighting G9712L-T5-WHESI Quick Start Manual Download Page 2

- 2 -

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

Fig. 1

Fig. 1

Fig. 3

Fig. 3

Fig. 2

Fig. 4

Fig. 5

Remove the old fixture. Make yourself a sketch of how the fixture 

is wired (index the sketch by wire color) or mark the wires 

themselves with masking tape and a pencil so you will know how to connect the wires to 

your new fixture. If several wires are involved or if the wiring seems more complicated and 

perhaps even includes a red wire, take note of the connections before you disconnect them.

WARNING:

 Shut off power at the circuit breaker or fuse panel 

before removing the old fixture (

Fig. 1

).

While holding the fixture up against the mounting surface, use 

a pencil to mark the locations of the keyhole slots onto the 

mounting surface (

Fig. 4

).

Drill a 1/16 in. pilot hole into the marked screw locations. You 

can also use an awl, or nail to dimple the screw holes. Start 

the screws, but do not tighten fully. Slide the fixture over until 

the narrow legs of the keyhole slots are under the heads of the 

screws (

Fig. 5

). Finish tightening the screws until they are 

firmly seated, and the fixture is tightly secured to the mounting 

surface. Replace the diffuser. 

Remove the diffuser by pulling back and up on the top edge of 

the diffuser using your fingertips (

Fig. 1

).

Remove the bulb from the fixture by placing your thumbs on 

the metal ends of the bulb. While applying slight pressure on 

the bulb, roll the bulb toward you until the contact 

pins on the ends of the bulb disengage from the

socket 

(Fig. 2).

 Pull the bulb straight out from the 

socket and set aside during mounting 

(Fig. 3).

DO NOT ALTER THE PLUG.

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. 

IMPORTANT SAFETY INSTRUCTIONS.

WARNING:

 To reduce the risk of 

FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

:

  1. Turn off/unplug and allow to cool before replacing bulb (lamp).

  2. Use only with a linear fluorescent bulb: 

G9712L-T5-WHESI Bulb #F8T5,    

 

  G9724L-T5-WHES-I Bulb #F14T5.

  3. Handle bulb(s) with care during replacing. The glass tube of bulb is very fragile and can    

  break easily.

IMPORTANT: 

The fluorescent bulb is included with your Good Earth Lighting® fixture. In order 

to protect the bulb during shipment, your bulb(s) may be packed in a separate area of the 

Mounting Instructions

1

2

3

4

1

2

packing materials. Additionally, your bulbs may already be placed into their respective 

sockets, but may have a protective support collar slipped over the bulb. Do 

NOT 

operate your 

fixture with this support collar in place. You can either cut this collar off, or remove the bulb 

from the sockets and slide the support collar off the bulb. Discard the corrugated support 

collar.

Before installation, plug in fixture to a 120V 60Hz electrical outlet to check for proper operation. 

Then, unplug and begin the installation.

SAVE THESE INSTRUCTIONS

DO NOT INSTALL THE FIXTURE WHILE IT IS PLUGGED INTO AN ELECTRICAL OUTLET! FOR 

INDOOR INSTALLATIONS ONLY.

Caution: the wattage of all the bulbs added together in one chain should 

NOT

 exceed 600 W. 

Installing more than that total wattage can overload the connector wiring and can result in a 

hazardous situation. These fluorescent light fixtures are available in 8 W and 14 W versions. 

You should identify each of the versions you have on hand, and add up the total number of 

bulbs to insure that it does not exceed 600 W.

Preparation

DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT

. If you presently have dimmer 

controls, you will need to remove them and replace them with regular electrical switches. If 

you have a three way dimmer, you will have to replace it with a regular three way switch.

If you are unfamiliar with electrical installations, we recommend you have a qualified 

electrician do your installation.

 

english

Important Safety Instructions

This unit has a polarized plug (one blade is wider than the other) as a safety feature. This plug 

will fit in a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the 

plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord 

unless plug can be fully inserted. Do 

NOT

 attempt to defeat this feature.

WARNING: SHOCK HAZARD

If your fixture is to be direct wired, you will no longer need your power cord, and it should be 

discarded. Do 

NOT

 remove the plastic receptacle cap that covers the input receptacle. 

DO 

NOT

 plug your power cord into light fixture.

Direct Wire Installation

Summary of Contents for G9712L-T5-WHESI

Page 1: ...Jeu de quincaillene Juego de piezas de instalaci n Power Cord Fil d almentation e lectrique Cable de alimentaci n Fixture Luminaire Aplique de luz Diffuser Diffuseur Difusor Bulb Ampoule Bombilla Con...

Page 2: ...lb is included with your Good Earth Lighting fixture In order to protect the bulb during shipment your bulb s may be packed in a separate area of the Mounting Instructions 1 2 3 4 1 2 packing material...

Page 3: ...ture must be properly grounded If you are unfamiliar with the methods of properly grounding your fixture consult a qualified electrician A copper ground wire is pre attached to your fixture If your el...

Page 4: ...ins of the bulb with the slot in the sockets Using your thumbs and forefinger press the metal ends of the bulb socket and roll the bulb forward until it rotates 90 degrees inside the socket making con...

Page 5: ...fluorescent sont disponibles en versions 8 w et 14 w Veuillez identifier chacune des versions que vous avez et additionner le nombre total d ampoules de chaque cat gorie pour vous assurer que la puiss...

Page 6: ...is du luminaire en serrant l attache depuis l int rieur du luminaire REMARQUE rappelez vous qu il est n cessaire que les vis d accouplement des fils soient orient es d une mani re vous permettant de s...

Page 7: ...Les conducteurs noirs du luminaire se raccordent au fil d alimentation noir et les conducteurs blancs du luminaire se raccordent au conducteur d alimentation blanc Serrez les serre fils correctement...

Page 8: ...e Les petits probl mes peuvent souvent tre r solus sans avoir besoin de recourir un lectricien Avant de faire quoi que ce soit sur le luminaire coupez l alimentation au niveau du disjoncteur pour vite...

Page 9: ...ufe polarizado un terminal es m s ancho que el otro como dispositivo de seguridad Este enchufe encajar en un tomacorriente polarizado solamente de una manera Si sigue sin encajar contacte a un electri...

Page 10: ...ntiene toda la torniller a necesaria para realizar una instalaci n normal Una vez que usted haya determinado la posici n en la que se montar el aplique de luz marque el destapadero correspondiente m s...

Page 11: ...uminaci n est siendo conectado utilizando una conexi n flexible o un cable NM el cable de conexi n a tierra del accesorio para iluminaci n y el cable de conexi n a tierra de la fuente de alimentaci n...

Page 12: ...ierra Hg LA L MPARA CONTIENE MERCURIO Man jela de acuerdo con las leyes de desechos www lamprecycle org or ou o 1 866 326 BULB www epa gov mercury spills index htm fluorescent Deseche la o las bombill...

Reviews: