2.4 Specifications
Artikel
20319
20327
Input voltage AC
230 V ±10% / 50 Hz ±10%
230 V ±10% / 50 Hz ±10%
Output voltage DC
0-30 V continuous
0-30 V continuous
Output current
0-3 A continuous
0-10 A continuous
Accuracy
CV 1x10
-4
+ 1 mV
CV 1x10
-4
+ 10 mV
CC 2x10
-3
+ 1 mA
CC 5x10
-3
+ 10 mA
Regulation of the load
CV < 1x10
-4
+ 2 mV
(for I < 6 A)
CV < 2x10
-4
+ 10 mV
CC < 2x10
-3
+ 2mA
CC < 5x10
-3
+ 10 mA
(for I > 6 A)
CV < 5x10
-3
+ 10 mV
CC < 5x10
-3
+ 20 mA
Periodic deviation
CV < 0,5 mV (rms) (5 Hz ~ 1 MHz) CV < 3 mV (rms)
CC < 2 mA (rms)
CC < 10 mA (rms)
Protection function
Current limiting
Display accuracy -
voltage
LED ± 1%
LED ± 1% + 2 digits
Display accuracy -
current
LED ± 2%
LED ± 2% + 2 digits
Dimensions
135 x 160 x 275 mm
360 x 165 x 265 mm
Weight
4.35 kg
11.00 kg
Mains fuse
250 V 2A T
250 V 2A T
Protection class
I
Tab. 3:
Specifications
3 Intended Use
We do not permit using the device in other ways like described in chapter
“Description and Function“ and „Safety Instructions“. Use the product only
in interior, closed and well ventilated rooms, like workshops.
Not attending to these regulations and safety instructions might cause fatal
accidents, injuries, and damages to persons and property.