33
INDEX
Introduction ...........................................33
Índex .....................................................33
Starting recommendations ....................33
System characteristics ...........................34
System operation...................................34
Door panel PVS-220 ...................................
Description..........................................35
Location .....................................36 to 37
Wiring ..................................................37
Final adjustements ..............................37
Push button label .................................38
Close the door panel...........................38
Power supply ..............................................
Installation...........................................39
Characteristics ....................................39
Lock release installation .........................39
370S colour monitor ...................................
Description..........................................40
Function push buttons .........................41
Call volume control .............................41
Configuration switches ........................41
Location bracket installation ................42
Wiring ..................................................43
Fix the monitor .....................................43
Screen settings ....................................44
Ring tone selection ..............................44
Intercom function................................44
Installation diagram ...................................
One or two door panels .......................45
Connection of an additional monitor...45
Sections chart .....................................46
Connection a.c. lock release...............46
Connection auxiliary device................46
Troubleshooting hints..............................47
STARTING RECOMMENDATIONS
O
O
O
O
O
O
O
O
O
O
Do not use excessive force when tightening the power supply connection block screws.
Install the equipment without the power connected.
Before connecting the system, check the connections between door panel, monitors and
the power supply connection.
Only use compatible 370S colour monitor.
Only use parallel or twisted cable (to sections see page 46).
Do not use single wire.
Do not double the cable to increase the section.
O
The entire installation must be at least 40 cm. away from any other installation otherwise
there is a risk that the audio signal be exposed to interference, or that the system does not
work correctly.
Always use 12 Vd.c. lock releases (cod. 20600149, not included in the kit).
Do not switch voltage higher than 12 Vd.c. / 1A between C and NO door panel terminals.
Both monitor and door panel are delivered with a protective film, to avoid scratches
INTRODUCTION
First of all we would like to thank and congratulate you for the purchase of this product
manufactured by Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001
certification and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy
with the legion of features this system offers. To obtain the maximum profit of these features and
a properly wired installation, we kindly recommend you to expend a few minutes of your time to
34
SYSTEM OPERATION
O
O
O
O
O
O
O
O
O
w
w
w
w
w
w
Video door entry system with simplified installation (polarised 2 wire bus).
Up to 2 access door panel.
O
Up to 2 monitors per installation.
Acoustic call acknowledgment signals.
Maximum distance between the door panel and the last monitor: 100m.
Maximum distance between power supply and monitor: 20m.
Door opening timed at 2 seconds.
D.C. lock release.
Contact free auxiliary for activating auxiliary devices, do not switch voltage and current higher
than 12Vcc/1A between C and NO door panel terminals.
370S Colour monitor
:
Autoswitch-on function.
Intercommunication function.
Activation auxiliary device.
Colour monitor 7".
w
Call volume control.
Brightness, contrast and colour control.
Different call tones which identify the call procedure: door panel and intercom.
O
To make a call, the visitor should press the over one of the push button ends, as it is shown on the
label of the push button. At this moment, the call will be received at the monitor(s) in the
apartment.
O
The call tone lasts for 40 seconds, unknown to the visitor, the picture is displayed in the monitor (s)
just a few seconds after the call is received. If the call is not answered in 40 seconds, the picture
will disappears.
O
To establish communication press push button monitor. The picture will disappears on the
second monitor (if exists).
O
The communication will last for 80 seconds or until press push button monitor again.
O
If during communication with a door panel, a call is made from a second door panel (if exists),
the monitor in communication will automatically enter in communication with the last calling
door panel.
O
To open the door, press the door release push button during call reception, communication or
SYSTEM CHARACTERISTICS