background image

SYSTEM OPERATION

O

To make a call the visitor should press the push button corresponding to the apartment he wishes to 
contact. An acoustic tone will be heard confirming the call is in progress once the push button has 
been pressed. At this moment the call will be received at the monitor (telephone) in the dwelling.
During the call the visitor can correct his call by pressing a push button corresponding to a different 
apartment, in which case the original call is cancelled.

O

In systems with several accesses doors, the other(s) door panel(s) will be automatically disconnected:
If a visitor tries to call from other door panel an acoustic tone will be heard confirming the system is 
busy and the led of busy system from informative window will lights (If it exists).

O

General door panel (EL501 mode): If the call is made from the general door panel, the inner door 
panel of the building called and other possible general door panel will remain automatically 
disconnected, if another visitor tries to call from an inner busy door panel or from another general 
door panel, an acoustic tone will be heard confirming the system is busy and the led of system busy 
will blink (in the general door panel). The door panels of the others inner buildings will remain free to 
be used.

O

General door panel (EL501 mode): In the case that the call is made from an inner door panel, the rest 
of inner door panels will remain free to be used. From general door panels only will be able to make 
calls to the inner buildings whose door panels are not in use, if the visitor tries to make a call to a busy 
inner door panel, an acoustic tone will be heard confirming the system is busy and the led of system 
busy from informative window will blink.

O

The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will 
appear on the master monitor without the visitor being aware of this. To see the picture in a slave 
monitor press the   push button, dissapearing the picture on the other monitor. If the call is not 
answered in 45 seconds, the system will be freed.

O

To establish communication pick up the monitor (telephone) handset.

O

The communication will last for one and a half minutes or until the handset is replaced. Once the 
communication has finished the system will be freed.

O

To open the door, press the door release push button during call or communication progresses: with 
one press, the door release operates during 3 seconds. During the lock release activation an acoustic 
tone will be heard on the door panel confirming the lock release is activated.

O

The monitor and telephones push buttons description is shown on pages 120, 125 & 129 respectively.

SYSTEM CHARACTERISTICS

w

Allows one of these functions at once, Configuration with dip switch   Sw1 (see page 129):

w

"Autoswitch-on" function.

w

Output for auxiliary relay activation (18Vdc/0,5 A maximum).

w

Call to a slave porter's exchange.

w

Intercommunication function with other monitor or telephone of the same apartment.

O

With Platea Plus monitors, addition to the T-940 Plus telephones features:

w

"Autoswitch-on" function.

w

"Video-spy" function with the communication channel remaining free.

w

Call to a slave porter's exchange.

w

Activation of two auxiliary devices: secondary telecamera, courtesy light, ...

w

B/W & Color monitor.

w

Brightness and contrast control (color control in case of color screen).

Coming from previous page

DOOR PANEL DESCRIPTION

oor panel description.

D

1xxx
2xxx

grille module

600

closing heads

3xxx

push buttons module

CE-6xx embedding boxes

Sound module

EL530
EL531
EL540

, on video systems with b/w camera.
, on video systems with color camera.
, on audio systems.

, on audio and video systems.

O

EL500 or EL501,

c

, (page 112).

perating modes

onfiguration with dip switch

, on systems with more than eight push buttons.

Push buttons

encoder

EL516SE

Microprocessed

circuit

EL500SE

Informative window

Informative window to indicate of a visual way that the system is busy. It is recommended

use the following types of installations:

- Buildings or backbones with more than one access.
- Systems with general door panels.

*

*

104

103

Summary of Contents for Stadio Plus T500SE ML

Page 1: ...En cas d effet Larsen r duire le volume jusqu disparition de celui ci Si l effet Larsen dispara t seulement lorsque le volume est au minimum il est possible qu il y ait un autre probl me O Effet Larse...

Page 2: ...installation wVideo door entry system with 3 common wires plus coaxial cable installation wVideo door entry system with 4 common wires plus twisted pair installation O Microprocessed circuit EL500SE...

Page 3: ...the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset O Th...

Page 4: ...s been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry...

Page 5: ...rcuit in the bottom flanges 2 by pressing the pcb board To assembly the EL516SE encoder screw the top tab of the case to the corresponding plastic lug of the embedding box In case of more than one enc...

Page 6: ...han one access wire all the push buttons and modules EL 516SE following the same order in all the door panels CP P8 B P7 P1 P6 P2 P5 P3 P4 Top view CP Black B Red P1 Green P2 Orange P3 Blue P4 Violet...

Page 7: ...o OFF coaxial cable RG 59 o RG 11 Set to ON twisted pair Selects if the door panel has telecamera or not In case of door panels without telecamera EL540 sound module set to ON Plus system loads the in...

Page 8: ...bone building Set a code between 1 and 120 for inner backbones up to 127 with coded panel and a code 0 for general door panel s To set the code use binary coding as shown on the next paragraph Factory...

Page 9: ...ry coding see page 113 nformative window connection I DOOR PANEL INSTALLATION The EL500SE microprocessor module supplies a cable with conector for the indication of busy system Insert the side of the...

Page 10: ...th the necessary adjustments as shown The telecamera has a pan and tilt mechanism built in to adjust the telecamera position In case of low light conditions an external illumination can be activated b...

Page 11: ...the activation of an optional second camera If not allows to make an intercom call or to activate the second camera If the handset is on the craddle allows the activation of an optional device If not...

Page 12: ...hanging the front film C MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION Locate the CN4 connector that s placed in the monitor base Remove the existing jumper and plug the EL562 module NOTE on this...

Page 13: ...s the monitor firmly To disassemble the monitor from the connector use a plain screwdriver to release the attachment clip Remove the monitor from the connector with special attention do not falls Swit...

Page 14: ...intercom call when the handset is not on the craddle This function is described on page 147 If the handset is on the craddle sends a panic call to the porter s exchanges that have enabled the receptio...

Page 15: ...e right front of the telephone To show that the system is ready for programming the door panel will reproduce a tone and the telephone led will blink At this moment the door release push button can be...

Page 16: ...one of the following functions Autoswitch on PA output call to a slave porter s exchange and intercommunication escripci n del microinterruptor de configuraci n D escription of programming push butto...

Page 17: ...lose the telephone P3 ON P3 SW1 Open the telephone to programming see page 130 Select in the SW1 dip switch the fuction mode for the auxiliary see page 129 and later press the P3 programming push butt...

Page 18: ...ut Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230110 0 SW2 SW2 Core max electrical resistence to 20 C Copper core Copper shield E...

Page 19: ...alla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW2 SW2 ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS Place this power supply as closest as possible to the first distributor S M Access door pa...

Page 20: ...Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SEC PRI ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS S M Access door panel Access door panel The installation diagra...

Page 21: ...in Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 FA...

Page 22: ...To install and configure properly d The installation diagram shows the connection of a video system with two general door panels and up to 120 inner door panels backbones buildings In case of more tha...

Page 23: ...D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 General door panel SW2 SW1 IMPORTANT NOTES To install and configure properly d The installation diagram...

Page 24: ...e 120 This facility disables the intercom function If both functions are required use A1 terminal to activate the second camera To activate this function press monitor push button at any moment with n...

Page 25: ...m facility between two units of the same apartment To enable this function check the following conditions One of the units has been configurated as master and the other unit as slave with intercom as...

Page 26: ...fade out If feedback don t dissapears refer to the following hint O Continuous audio feedback w Check that A terminal is not shortcircuited with other terminals O Door open function no operates w Rem...