SAFETY PRECAUTIONS

INTRODUCTION

STARTING RECOMMENDATIONS

INDEX

First of all we would like to thank and congratulate you for the purchase of this product manufactured by 
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification 
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the 
legion of features this system offers. To obtain the maximum profit of these features and a properly wired 
installation, we kindly recommend you to expend a few minutes of your time to read this manual.

O

O

O

O

O

Do not use excessive force when tightening the power supply connector screws.
The entire installation must be at least 

40cm

. away from any 

other installation

.

Before to connect the system, check the connections between door panel, monitors, telephones, and 
the transformer connection. Do always follow the enclosed information.
Each time the power supply is restarted, or after a modification, the system will remain blocked during 
30 seconds.
Always use RG-59 B/U MIL C-17 or RG-11 coaxial cables, (see page 134). 

Never use coaxial 

antenna cable.

 In installations no longers than 100m., 

Golmar RAP-5130

 cable can be used.

Introduction......................................101
Index ...............................................101
Starting recommendations..................101

System characteristics ..............102 to 103
System operation...............................103
Door panel installation.............................

Description ....................................104
Embedding box positioning ....105 to 106
Door panel modules assembly ..........106
Electronic modules assembly ............107
Door panel fixing ............................108
Place informative window label .........108
Push buttons wiring................109 to 110
Push buttons coding ........................111
EL500SE configuration ............112 to 113
Programming (general panel) .114 to 116
Informative window connection.........116
Lamps wiring ..................................117
Final adjustments ............................117

Power supply installation.....................118
Lock release installation .....................118
Platea Plus monitor ..................................

Description ....................................119
Function push buttons......................120
EL562 module................................121

Safety precautions .............................102

End of line resistor ...........................121
Front film replacement .....................121
Monitor connector description ..........122
Monitor installation .........................123
Programming .................................124

T-940 Plus telephone ...............................

Description ....................................125
Function push buttons......................125
Telephone installation......................126
Programming .................................127

T-740 Plus telephone ...............................

Description ..........................128 to 129
Function push buttons......................129
Telephone installation......................130
Programming .................................131

Installation diagrams ...............................

Connection of an a.c. lock release.....132
Link of several power supplies ...........132
Video installation with coaxial.......133-134
Video installation without coaxial ..135-136
Audio installation.......................137-138
Video installation (general panel) ..139-142
Audio installation (general panel) ..143-144

Optional connections ...................145-148
Troubleshooting hints.........................149
Compliance .....................................151

SYSTEM CHARACTERISTICS

O

Microprocessed system with simplified installation:

w

Audio door entry system with 4 common wires installation.

w

Video door entry system with 3 common wires plus coaxial cable installation.

w

Video door entry system with 4 common wires plus twisted pair installation.

O

Microprocessed circuit EL500SE with two operating modes(EL500 or EL501).

O

Unlimited number of door panels (access) being not necessary the use of switching units.

O

Up to 120 monitors/telephones per installation or backbone.

O

General door panel (EL501 mode): Up to 120 monitors/telephones, distributed in max. 120 buildings.

O

EL560 module for video installations with twisted pair cable, integrated in EL500SE circuit.

O

Communications resistor for the system UNO or PLUS, integrated in EL500SE circuit.

O

Acoustic busy channel and call acknowledgement signals.

O

Door opening timed at 3 seconds.

O

Input for external door release push button (timed at 3 or 15 seconds).

O

a.c or d.c lock release operated by relay.

O

Up to three monitors or telephones in the same apartment without additional power supplies.

O

With T-940 Plus telephones:

w

Privacy on audio communications.

w

Three-position control for call volume: maximum, medium and minimum.

w

Intercommunication function with other monitor or telephone of the same apartment.

w

Input for external door bell push button.

w

Output for additional call repeater.

w

Call to a master porter's exchange.

w

Panic call to the porter's exchange.

w

Different call reception tones depending where the call is comming from: main or slave door 

panels, door bell push button, intercom, ...

O

With T-740 Plus telephones, addition to the above features:

w

Three-position control for call volume: maximum, medium and off.

w

Input for external door release push button.

Continue

O

O

O

O

w

w

w

w

w

O

w

w

w

O

O

Install or modify the equipment 

without the power connected

.

The installation and handling of these equipments must be performed by 

authorised personnel

.

The entire installation must be at least 

40 cm

. away from any 

other installation

.

With power supply:

w

Do not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
Do not block ventilation holes of the unit so that air can circulate freely.
To avoid damage, the power supply has to be firmly fixed.
To avoid an electrical shock, neither remove the protection cover nor handle the connected wire in 

the terminals. 

With monitor, telephones and distributor:

Do not use excessive force when tightening the connector screws.
Install the power supply in a dry and protected place without risk of drip or water projections.
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.

w

Do not block ventilation holes of the equipments so that air can circulate freely.

Remember, the installation and handling of these equipments must be performed by authorized 
personnel and in the absence of electrical current.
Do always follow the enclosed information.

Summary of Contents for Stadio Plus T500SE ML

Page 1: ...En cas d effet Larsen r duire le volume jusqu disparition de celui ci Si l effet Larsen dispara t seulement lorsque le volume est au minimum il est possible qu il y ait un autre probl me O Effet Larse...

Page 2: ...installation wVideo door entry system with 3 common wires plus coaxial cable installation wVideo door entry system with 4 common wires plus twisted pair installation O Microprocessed circuit EL500SE...

Page 3: ...the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset O Th...

Page 4: ...s been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry...

Page 5: ...rcuit in the bottom flanges 2 by pressing the pcb board To assembly the EL516SE encoder screw the top tab of the case to the corresponding plastic lug of the embedding box In case of more than one enc...

Page 6: ...han one access wire all the push buttons and modules EL 516SE following the same order in all the door panels CP P8 B P7 P1 P6 P2 P5 P3 P4 Top view CP Black B Red P1 Green P2 Orange P3 Blue P4 Violet...

Page 7: ...o OFF coaxial cable RG 59 o RG 11 Set to ON twisted pair Selects if the door panel has telecamera or not In case of door panels without telecamera EL540 sound module set to ON Plus system loads the in...

Page 8: ...bone building Set a code between 1 and 120 for inner backbones up to 127 with coded panel and a code 0 for general door panel s To set the code use binary coding as shown on the next paragraph Factory...

Page 9: ...ry coding see page 113 nformative window connection I DOOR PANEL INSTALLATION The EL500SE microprocessor module supplies a cable with conector for the indication of busy system Insert the side of the...

Page 10: ...th the necessary adjustments as shown The telecamera has a pan and tilt mechanism built in to adjust the telecamera position In case of low light conditions an external illumination can be activated b...

Page 11: ...the activation of an optional second camera If not allows to make an intercom call or to activate the second camera If the handset is on the craddle allows the activation of an optional device If not...

Page 12: ...hanging the front film C MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION Locate the CN4 connector that s placed in the monitor base Remove the existing jumper and plug the EL562 module NOTE on this...

Page 13: ...s the monitor firmly To disassemble the monitor from the connector use a plain screwdriver to release the attachment clip Remove the monitor from the connector with special attention do not falls Swit...

Page 14: ...intercom call when the handset is not on the craddle This function is described on page 147 If the handset is on the craddle sends a panic call to the porter s exchanges that have enabled the receptio...

Page 15: ...e right front of the telephone To show that the system is ready for programming the door panel will reproduce a tone and the telephone led will blink At this moment the door release push button can be...

Page 16: ...one of the following functions Autoswitch on PA output call to a slave porter s exchange and intercommunication escripci n del microinterruptor de configuraci n D escription of programming push butto...

Page 17: ...lose the telephone P3 ON P3 SW1 Open the telephone to programming see page 130 Select in the SW1 dip switch the fuction mode for the auxiliary see page 129 and later press the P3 programming push butt...

Page 18: ...ut Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230110 0 SW2 SW2 Core max electrical resistence to 20 C Copper core Copper shield E...

Page 19: ...alla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW2 SW2 ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS Place this power supply as closest as possible to the first distributor S M Access door pa...

Page 20: ...Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SEC PRI ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS S M Access door panel Access door panel The installation diagra...

Page 21: ...in Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 FA...

Page 22: ...To install and configure properly d The installation diagram shows the connection of a video system with two general door panels and up to 120 inner door panels backbones buildings In case of more tha...

Page 23: ...D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 General door panel SW2 SW1 IMPORTANT NOTES To install and configure properly d The installation diagram...

Page 24: ...e 120 This facility disables the intercom function If both functions are required use A1 terminal to activate the second camera To activate this function press monitor push button at any moment with n...

Page 25: ...m facility between two units of the same apartment To enable this function check the following conditions One of the units has been configurated as master and the other unit as slave with intercom as...

Page 26: ...fade out If feedback don t dissapears refer to the following hint O Continuous audio feedback w Check that A terminal is not shortcircuited with other terminals O Door open function no operates w Rem...

Reviews: