background image

To telephones

To telephones

udio installation with general door panel 

to large residential complexes.

A

1,50mm²

2,50mm²

0,25mm²

0,25mm²

Terminal

SECTIONS CHART

100m.

Distance

300m.

A , A , A, D

in

out

For greater distances contact our technical support department.

+,

–, CV1, CV2

SEC

PRI

~

~

+ +

-

-

SW2

FA-Plus o FA-Plus/C

Main

D

Malla

V

in-

A

in

A

out

V

in+

V

out-

V

out+

CN2

+

AP - - +

CV1

CV2

-

+12

-

SW1

SW1

D

Malla

V

in-

A

in

A

out

V

in+

V

out-

V

out+

CN2

+

AP - - +

CV1

CV2

-

+12

-

SW2

FA-Plus o FA-Plus/C

SEC

PRI

~

~

+ +

-

-

Main

D

Malla

V

in-

A

in

A

out

V

in+

V

out-

V

out+

CN2

+

AP - - +

CV1

CV2

-

+12

-

FA-Plus/C

rev.938072

SEC

PRI

230

Main

-

-

110 0

+ +

General door panel

SW2

SW1

IMPORTANT NOTES:

To install and configure properly, d
The installation diagram shows the connection of an audio system with one general door panel 

and up to 120 inner door panels (backbones/buildings).

In case of more than one general door panel, wire them as it shows in the video installation 

diagram, (see page 139).

o always follow the enclosed information.

Inner door panel

BACKBONE 1

BACKBONE 120

Inner door panel

EL501 mode

EL500 mode

S

M

EL500 mode

M

BACKBONE 0

144

143

GENERAL DOOR PANEL

INSTALLATION DIAGRAMS

M =Master.

S  =Slave.

Summary of Contents for Stadio Plus T500SE ML

Page 1: ...En cas d effet Larsen r duire le volume jusqu disparition de celui ci Si l effet Larsen dispara t seulement lorsque le volume est au minimum il est possible qu il y ait un autre probl me O Effet Larse...

Page 2: ...installation wVideo door entry system with 3 common wires plus coaxial cable installation wVideo door entry system with 4 common wires plus twisted pair installation O Microprocessed circuit EL500SE...

Page 3: ...the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system will be freed O To establish communication pick up the monitor telephone handset O Th...

Page 4: ...s been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry...

Page 5: ...rcuit in the bottom flanges 2 by pressing the pcb board To assembly the EL516SE encoder screw the top tab of the case to the corresponding plastic lug of the embedding box In case of more than one enc...

Page 6: ...han one access wire all the push buttons and modules EL 516SE following the same order in all the door panels CP P8 B P7 P1 P6 P2 P5 P3 P4 Top view CP Black B Red P1 Green P2 Orange P3 Blue P4 Violet...

Page 7: ...o OFF coaxial cable RG 59 o RG 11 Set to ON twisted pair Selects if the door panel has telecamera or not In case of door panels without telecamera EL540 sound module set to ON Plus system loads the in...

Page 8: ...bone building Set a code between 1 and 120 for inner backbones up to 127 with coded panel and a code 0 for general door panel s To set the code use binary coding as shown on the next paragraph Factory...

Page 9: ...ry coding see page 113 nformative window connection I DOOR PANEL INSTALLATION The EL500SE microprocessor module supplies a cable with conector for the indication of busy system Insert the side of the...

Page 10: ...th the necessary adjustments as shown The telecamera has a pan and tilt mechanism built in to adjust the telecamera position In case of low light conditions an external illumination can be activated b...

Page 11: ...the activation of an optional second camera If not allows to make an intercom call or to activate the second camera If the handset is on the craddle allows the activation of an optional device If not...

Page 12: ...hanging the front film C MONITOR ADJUSTMENTS MONITOR CONNECTOR DESCRIPTION Locate the CN4 connector that s placed in the monitor base Remove the existing jumper and plug the EL562 module NOTE on this...

Page 13: ...s the monitor firmly To disassemble the monitor from the connector use a plain screwdriver to release the attachment clip Remove the monitor from the connector with special attention do not falls Swit...

Page 14: ...intercom call when the handset is not on the craddle This function is described on page 147 If the handset is on the craddle sends a panic call to the porter s exchanges that have enabled the receptio...

Page 15: ...e right front of the telephone To show that the system is ready for programming the door panel will reproduce a tone and the telephone led will blink At this moment the door release push button can be...

Page 16: ...one of the following functions Autoswitch on PA output call to a slave porter s exchange and intercommunication escripci n del microinterruptor de configuraci n D escription of programming push butto...

Page 17: ...lose the telephone P3 ON P3 SW1 Open the telephone to programming see page 130 Select in the SW1 dip switch the fuction mode for the auxiliary see page 129 and later press the P3 programming push butt...

Page 18: ...ut Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230110 0 SW2 SW2 Core max electrical resistence to 20 C Copper core Copper shield E...

Page 19: ...alla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW2 SW2 ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS Place this power supply as closest as possible to the first distributor S M Access door pa...

Page 20: ...Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SEC PRI ONE OR SEVERAL ACCESSES DOORS INSTALLATION DIAGRAMS S M Access door panel Access door panel The installation diagra...

Page 21: ...in Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 SW1 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 FA...

Page 22: ...To install and configure properly d The installation diagram shows the connection of a video system with two general door panels and up to 120 inner door panels backbones buildings In case of more tha...

Page 23: ...D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 FA Plus C rev 938072 SEC PRI 230 Main 110 0 General door panel SW2 SW1 IMPORTANT NOTES To install and configure properly d The installation diagram...

Page 24: ...e 120 This facility disables the intercom function If both functions are required use A1 terminal to activate the second camera To activate this function press monitor push button at any moment with n...

Page 25: ...m facility between two units of the same apartment To enable this function check the following conditions One of the units has been configurated as master and the other unit as slave with intercom as...

Page 26: ...fade out If feedback don t dissapears refer to the following hint O Continuous audio feedback w Check that A terminal is not shortcircuited with other terminals O Door open function no operates w Rem...