Do not overtighten the screws on the Bus connection terminals of the M-IP-GB2 module.
-
Before connecting the device to the mains, check the connections of the M-IP-GB2 module, FA-GB2/B power supply,
distributors and monitors.
-
Use the Golmar
cable (2x1mm ).
RAP-2150
2
-
Always follow the instructions contained in this manual.
CHARACTERISTICS
INTRODUCTION
First of all, we thank and congratulate you for purchasing this product.
Our commitment to achieving the satisfaction of customers like you is manifested through our ISO-9001 certification
and the manufacture of products like the one you have just purchased.
Its advanced technology and strict quality control will ensure that customers and users enjoy the numerous features
that this device offers. To get the most out of them and ensure proper operation from day one, we recommend that
you read this instruction manual.
CONTENTS
2
SET-UP WARNINGS
I
.................................................................................................................................................................2
ntroduction
Contents
.................................................................................................................................................................... 2
Set-up warnings
................................................................................................................... ..... .. 2
............................. ..
.
Description of terminals
...................................................................................................................................... ...... 3
.
.
.
Mounting
.................................................................................................................................................................... 3
.
Operating mode
.................................................................................................................................. ..... ..4
............ .....
Connections diagram
........................................................................................................................................ ... 5
......
.
MEMORY MODULE: M-IP-GB2
Date/time setting
...................................................................................................................................................... .6
.
.
-
M-IP-GB2 memory module with simplified wiring (non-polarised 2-wire bus).
-
M-IP-GB2 memory module for the GB2 system:
w
'Building' installation:
-
Up to 1 M-IP-GB2 memory unit.
-
The memory unit must be installed on the monitors Bus side (see wiring diagram p. 5).
-
Each apartment can only watch its own recordings.
-
The system monitor must support the image recording function (videos/photos).
-
When connected to the M-IP-GB2 unit, the photo memory and calendar function will be activated immediately; for the
video memory function, a 16 GB Class 10 MicroSD card (not included) is required.
-
The system monitor must support the image recording function.
-
The monitor has an auto-recording function.
-
The time for each video recording in the memory module is 9 seconds (16 GB Class 10 MicroSD card required).
-
Recorded videos/photos can be deleted from the monitor.
-
Videos/photos can be played on the monitor if the system is in standby. If a call is received while a video/photo is being
viewed, playback will be interrupted to enable the call to be answered immediately.
-
In building systems, each apartment can only watch its own recordings.
-
It is recommended to check the videos/photos of missed calls stored and delete any old ones.
SAFETY PRECAUTIONS
-
Always disconnect the power supply
before installing or making modifications to the device.
- The fitting and handling of these devices must be carried out by
authorised personnel.
- The wiring must run at least
.
40cm away from any other wiring
- Install the module in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Ensure that the air vents are free from obstruction so that air can circulate freely.
- To prevent damage, the M-IP-GB2 module must be firmly secured in place.
Safety precautions
.................................................................................................................................. ........ 3
...........
.
Notes ................. 7
........................................................................................................................................................ .