POWER SUPPLY INSTALLATION
LOCK RELEASE INSTALLATION
L
ock release installation
.
If the lock release will be installed in a metal door,
use a Ø3,5mm. drill and tap the hole
In case of wood door, use a Ø3mm. drill
.
.
M 4 x 8
DIN-7972
DIN-963
D
.
etail of the FA-PLUS/C ver. 938072 power supply installation
To install the power supply directly on the wall, drill two
holes of Ø6mm. and insert the wallplugs Fix the
transformer with the specified screws
.
.
The power supply can be installed on a DIN 46277
guide simply pressing it To disassemble the power
supply from the DIN guide, use a plain screwdriver
to lever the flange as shown on the picture
.
.
The FA-PLUS/C power supply uses 6 units over DIN guide.
Replace the protection cover once the input terminals have been wired.
.
The power supply must be installed in a dry and
protected place It's recommended to protect
the power supply by using a thermo-magnetic
circuit breaker
.
.
IMPORTANT: T
.
he lock release must be 12V direct or alternating current,
(see page 121)
110
DIN 46277
DOOR PANEL INSTALLATION
F
inal adjustments
.
L
amps wiring
.
Once the nameplate labels are placed, wire the lamps
from different modules and connect them to terminals
L1 and L2 of the sound module
If the number of door panel lamps is higher than 6,
connect a TF-104 transformer between ~1 and ~2
terminals of the sound module and change JP2 jumper
position
Don't change JP1 jumper position JP1 and JP2 jumpers are placed
on the left side of the sound module terminal connection block
.
.
NOTE:
.
.
If the TF-104 transformer with alternating current lock release is also used, wire
~1/~2 terminals of the sound module with CV1/CV2 terminals respectively of the
EL-500/R5 module.
C
.
lose the door panel
Fix the door panel by using the supplied screws and washers
Finish the door panel assembly by pressing the closing heads
If it were necessary to open the door panel once closed, use a
plain screwdriver to remove the closing heads
.
.
.
If after starting the system it's considered that the audio
volume isn't correct, proceed with the necessary
adjustments as shown
The telecamera has a pan and tilt mechanism
If the orientation is not adequate then correct its
position
In case of low light conditions, an external illumination
can be activated by connecting a SAR-12/24 relay
between terminals '+H' and 'L2' of the sound module
.
.
.
.
109
IMPORTANT:
.
See document TSAR-12/24 for its connection and characteristics.
The power to the SAR-12/24 relay must not
exceed 1,8A to 30Vdc/250 Vac