IM054B2 – June 2010
10
8.
SERVICING
SERVICING
Any mechanical product no matter how well made, will eventually require some service
attention. This equipment will need less service if given normal care and frequent
cleaning. Have a Gas Company or your serviceman check the equipment regularly.
Goldstein Salamanders are engineered for serviceability. Any part can be quickly and
easily removed if necessary for cleaning, service or replacement. Parts are accessible
from the front of the appliance.
All burners & pilots can be serviced without removing any panels. To remove the
GASCOCK
you will need to remove the control knobs and front control panel to get to
them.
MAIN BURNERS
Heavy Duty Infra Red Burners.
CONTROL COCKS
These are threaded into the inlet manifold and may be removed from underneath the
appliance. If the appliance cannot be adjusted to operate correctly, contact the gas
supplier or the manufacturers.
The gas control knobs control the flow of gas to each of the burners. A quarter of a
turn anti-clockwise puts the tap in a fully opened position.
TO REMOVE GAS INJECTOR OR BURNER
Gas Injectors
are located in the inlet to the burners. To remove injectors, turn the gas
off at the gas cock. The injectors can be removed by undoing flare nut on elbow, then
screwing out elbow or undoing nipple in elbow.
Burners
are removed by taking off the enamelled top. There are two screws holding
the back of the Burner. Push back burner will fall down.
NOTICE
PLEASE RETURN YOUR WARRANTY CARD
FAILURE TO DO SO WILL VOID WARRANTY
ON THE EQUIPMENT
NOTE:
‘DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS
APPLIANCE WHILE IT IS IN OPERATION’.