— 32 —
CHECK : 1. TOUCH KEY BOARD (START KEY FUNCTION)
PROBLEM C :
Display does not start countdown when START key is touched.
1
Continuity
OK
Normal
circuit board
Normal
contact
SEQUENCE
Runs
RESULT
Replace
circuit board
1
PROBLEM D :
Unit operation seems to be normal
but little or no heating is produced in oven load.
Check operation
of fan motor
when START
key is touched.
Normal
operation
No
operation
Measure resistance
of H.V. capacitor
(See page 23)
Normal
resistance
Replace
magnetron
Runs
Runs
Check contact of
connector S1.
No continuity
Normal primary
switch
Runs
Contact
OK
Poor contact
Correct
seating
Adjust or replace door sensing
sensing switch (See page 3)
CHECK: 1. AIR VENTS
Resistance
incorrect
THERMOSTAT
Jumper across
terminals of
THERMOSTAT by
using jumper lead.
Replace
fan motor
Replace
circuit board
Normal
circuit board
Runs
Runs
Resistance
incorrect
Replace H.V.
capacitor
Normal H.V.
capacitor
Normal
magnetron
Normal
fan motor
Normal
resistance
Runs
Check continuity of connector
CN2 between pin 1(PK)
and pin 3(BL) when the
door is closed.
Replace
thermostat
Runs
Normal
thermostat
Normal
operation
No
operation
Measure resistance
of fan motor
38 8 ohms.
+_
33
NO
Summary of Contents for MV-1155W
Page 8: ...6 OVERALL CIRCUIT DIAGRAM A SCHEMATIC DIAGRAM 7 ...
Page 40: ...CONTROLLER PARTS 38 WTT028 WTT021 WTT021 268711 24810P 26638A 07 23572A 24781M WTT021 EV ...
Page 42: ...LATCH BOARD PARTS 40 WSZ085 43500A 466001 466004 466002 43510A 466003 43501A EV ...
Page 45: ...INTERIOR PARTS III 43 WTT021 53551S 53551L WSZ002 WSZ002 53551R 568772 WTT021 WTT021 EV ...
Page 48: ......