— 24 —
COMPONENTS
TEST PROCEDURE
RESULTS
SWITHCHES
(Wire leads are
removed)
Check for the continuity of the switch
with an ohm-meter
DOOR OPEN
DOOR CLOSED
Secondary
Interlock
Interlock
Monitor
Primary
Interlock
Lamp
Switch
●
The sevice personnel should replace all of the monitored safety interlock
switches and monitor switch if the oven has been rendered inoperative due to
the failure of the monitored safety interlock(s).
●
Be sure to connect the monitor switch after replacement and to check interlock
monitor continuity.
NOTE:
After checking for the continuity of switches, make sure that they are correctly
connectly connected.
Terminals "COM" and
"NO" of switch
Terminals "COM" and
"NO" of switch
Terminals "COM" and
"NC" of switch
Terminals "COM" and
"NC" of switch
Terminals "COM" and
"NO" of switch
NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
CIRCUIT BOARD See page 30 for "CHECKOUT PROCEDURES FOR CIRCUIT BOARD".