— 27 —
COMPONENTS
TEST PROCEDURE
RESULTS
RELAY 2
RELAY 9
POWER
LEVEL
1
4 sec
18 sec
2
6 sec
16 sec
3
8 sec
14 sec
4
10 sec
12 sec
5
12 sec
10 sec
6
14 sec
8 sec
7
16 sec
6 sec
8
18 sec
4 sec
9
20 sec
2 sec
10
22 sec
0 sec
Check for continuity of the relay 2 with
an ohm-meter.
(Remove wire leads from relay 2 and
operate the unit on microwave cooking
mode.)
Figure. 41
Check for continuity of relay 9 with an
ohm-meter.
(Remove wire leads from relay 9 and
operate the unit on convection
cooking mode.)
Figure 42
STAND-BY
CONDITION
STAND
CONDITION
RELAY 2
RELAY 9
NOTE:
●
A MICROWAVE ENERGY TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS SERVICED FOR
ANY REASON.
●
MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
●
WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE CONNECTOR,
NOT THE WIRES.
Summary of Contents for MV-1155W