— 23 —
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH-VOLTAGE
CAPACITOR
HIGH-VOLTAGE
DIODE
Normal reading:
Momentarily indicates several
ohms, and then gradually
returns to infinite ohms.
Abnormal reading:
Indicates continuity or infinite
ohm from the beginning.
Normal reading:
Infinite.
Abnormal reading:
Indicates continuity.
Normal reading:
Continuity
Abnormal reading:
Infinite.
Normal reading:
Infinite.
Abnormal reading:
continuity.
Measure the resistance:
1) Terminal to terminal.
Figure 31-a
1) Terminal to case.
Figure 31-b
Measure the continuity
1) Forward
(Ohm-meter on Rx10000 scale.)
Figure 32-a
2) Reverse
Figure 32-b
Ohm- meter
Ohm- meter
Ohm- meter
Ohm- meter