Golden engineering XRS-3 Operator'S Manual Download Page 11

10

>HOME

MENU

PRESETS

PULSES: _ _ _ _
DELAY: _ _ _ _

HOME

>MENU

PRESETS

SET PULSE

LIFE PC

SET DELAY

RESET PC

TRAINS

SETTINGS

HOME

- MENU

PRESETS

SET PULSE COUNT

>SET PULSE

LIFE PC

 _ _ _ PULSES

SET DELAY

RESET PC

TRAINS

SETTINGS

BACK

SAVE

HOME

- MENU

PRESETS

SET DELAY TIME

SET PULSE

LIFE PC

_ _ _ SECONDS 

>SET DELAY

RESET PC

TRAINS

SETTINGS

BACK

SAVE

HOME

- MENU

PRESETS

SET PULSE TRAINS

SET PULSE

LIFE PC

 _ _ _ PULSE TRAINS:

SET DELAY

RESET PC

 _ _ _ SECONDS BETWEEN: 

>TRAINS

SETTINGS

BACK

SAVE

HOME

- MENU

PRESETS

LIFETIME PULSE COUNT

SET PULSE

>LIFE PC

SET DELAY

RESET PC

_ _ __ _ _ PULSES

TRAINS

SETTINGS

HOME

- MENU

PRESETS

RESETTABLE COUNTERS

SET PULSE

LIFE PC

#1: _ _ _ _

>RESET

SET DELAY

>RESET PC

#2: _ _ _ _

  

RESET

TRAINS

SETTINGS

  BACK

HOME

- MENU

PRESETS

SETTINGS

BACKLIGHT

SET PULSE

LIFE PC

>BACKLIGHT

FEEDBACK

ON

OFF

SET DELAY

RESET PC

X-RAY INFO

TRAINS

>SETTINGS

BACK

SETTINGS

FEEDBACK

BACKLIGHT

>FEEDBACK

INDIVIDUAL PULSE

X-RAY ON / X-RAY OFF

BACK

BACK

SETTINGS

X-RAY INFO

BACKLIGHT

FEEDBACK

SOFTWARE _ _ _

>E-RAY INFO

  SERIAL # _ _ _  

  HEAD # _ _ _

BACK

  BACK

HOME

MENU

- PRESETS

PRESET #1

PRESET #1

> PRESET #1

PULSES: _ _ _ _

DELAY: _ _ _ _

  PULSES: _ 50

DELAY: 15

  PRESET #2

TRAINS: _ _ _ _

  BTWN: _ _ _ _

  TRAINS: 05

  BTWN: 45

  PRESET #3

BACK

RECALL

>SAVE

BACK

RECALL

>SAVE

HOME

MENU

- PRESETS

PRESET #1

> PRESET #1

  PULSES: _ 50

DELAY: 15

  PRESET #2

  TRAINS: 05

  BTWN: 45

  PRESET #3

BACK

>RECALL

SAVE

To Enter/Save Presets

1. Enter desired settings (Pulse, Delay Time, Pulse Trains) from main menu as shown above
2. Go to Preset Menu
3. Select Preset #
4. Select SAVE

To Recall Presets

1. Go to Preset Menu
2. Select Preset #
3. Select Recall

Summary of Contents for XRS-3

Page 1: ...OPERATOR S MANUAL MARCH 2018 Golden Engineering Portable X ray Technology...

Page 2: ...ERATING PRECAUTIONS 8 EXCLUSION ZONE 8 PULSE SETTINGS 8 6 0 NAVIGATING THE MENU 9 7 0 MAINTENANCE 11 DOSE MEASUREMENT 11 TUBE REPLACEMENT 11 8 0 TROUBLE SHOOTING 11 9 0 INSTRUCTIONS FOR SERVICE 12 REM...

Page 3: ...dge and or a pocket dosimeter consistent with the appropriate federal territorial or provincial standards note an electronic dosimeter will not detect the XRS3 radiation pulses Due to the short pulse...

Page 4: ...mount The identi cation label located on the bottom of the generator lists the manufacturer s name and address model number serial number weight volt amp and production date BATTERY PACK The standard...

Page 5: ...igit LCD Home displays number of pulses selected and delay time before the rst pulse Home will also indicate if multiple pulse trains have been entered Arrows allow operator to scroll through various...

Page 6: ...ABLE CONNECTOR Lemo K series ve pin connector located on the back of the control module beneath the battery receives the remote cable or imaging system cable POSITIVE REMOTE CABLE CONNECTOR BATTERY TE...

Page 7: ...ulsed 7 As the High Voltage Switch is closed a high voltage transient of approximately 270 000 volts and 25 nanoseconds in duration is applied across the x ray tube generating x rays The closing of th...

Page 8: ...7 5 0 OPERATING INSTRUCTIONS The following are basic operation instructions to take an X ray image using the XRS3 Certain applications may require modi cations to these basic procedures...

Page 9: ...feet 3m behind the X ray unit and clear all personnel at least 10 feet 3m behind the unit or at least 100 feet 30m from the front of the unit before pulsing The exclusion zone below should be a contro...

Page 10: ...pulse setting LCD ERROR MESSAGE Low Battery Battery voltage is too low to pulse the XRS3 Charge the battery PWM not running Could occur at the start of a pulse train or during a pulse train Power uni...

Page 11: ...2 _ _ _ _ RESET TRAINS SETTINGS BACK HOME MENU PRESETS SETTINGS BACKLIGHT SET PULSE LIFE PC BACKLIGHT FEEDBACK ON OFF SET DELAY RESET PC X RAY INFO TRAINS SETTINGS BACK SETTINGS FEEDBACK BACKLIGHT FEE...

Page 12: ...the tube s output will decrease slowly with use If the tube is broken or the glass cracks the tube output will cease immediately 8 0 TROUBLESHOOTING SYMPTOM TEST ACTION No power on light Check batter...

Page 13: ...he control module 3 Remove cable connecting the boards 4 Control Module Removed 1 2 3 4 Remove keyswitch connector Remove 3 screws holding processor board to top Remove processor board Disconnect ribb...

Page 14: ...ited warranty customer must ship the entire unit or the component believed to be defective to Golden Engineering post paid Golden Engineering assumes no liability for units or components shipped until...

Page 15: ...onds ELECTRICAL AND THERMAL CHARACTERISTICS Battery voltage 18 volts 20 volts Battery type Li Ion Battery recharge time One Hour Current draw 20 amps 18 20 volt battery Current ow 0 25 mA Temperature...

Page 16: ......

Reviews: