![background image](http://html.mh-extra.com/html/goldair/gd330/gd330_operating-instructions-manual_2239896008.webp)
Operating Your Dehumidifier
TIMER FUNCTION
The appliance is fitted with a timer that will turn the unit off after the desired time has elapsed.
You can select between 1, 2, 4, 8 hours of running time. When the selected amount of running time has
expired, the unit will turn off.
ION FUNCTION
Switch the Ionizer (air purifier) On or Off when desired. The LED light will blink when turned on.
WATER TANK FULL INDICATOR
When the water tank is full, an alarm will sound 10 times. The LED light on the control panel will illuminate,
and the unit will stop operating.
The water tank must be removed, emptied and reinstalled before the unit will operate again.
ALARM
When the Alarm LED on the control panel has illuminated, the unit will stop operating. Check that the air
filter is clean. If the alarm continues then the unit has developed a fault.
Contact the place of purchase or the Goldair Customer Services Team, the unit will need to be returned or
sent to a qualifiedelectrical person for examination, electrical service or repair.
FAST DEHUMIDIFICATION (H)
In the Fast dehumidification (H) setting, the air velocity is accelerated and can aid in drying wet/damp
clothes.
PLEASE NOTE: water from clothes must not drip onto the unit, as this may damage the unit
and/or raise the risk of electric shock.
WATER DRAINAGE
If desired, it is possible to connect a drainage tube (not supplied) to the appliance for permanent water
drainage. If this option is desired you will need to purchase a suitable tube from your local hardware retailer
(Goldair does not hold tubes as spare parts).
Connect the drainage hose to the drain spout and ensure that the end of the hose is lower than the drain
opening, otherwise the water will not drain and flooding may occur. Also ensure the water tank is in position
(in the unit) otherwise the continuous drainage will not operate. Place the end of the drainage hose in a
drainage outlet. When you no longer wish to use the permanent water drainage, disconnect the drainage
tube from the device. Ensure that the water containeris positioned correctly.
DRAIN SPOUT
WATER TANK FULL INDICATOR