- Chapter 11 - Troubleshooting
Windrow 2500L Operator’s Manual MY18 - REV 1
Flow Meter & Controller
PROBLEM
COMMON CAUSES
COMMON SOLUTION
Application rate is
inaccurate, unstable
or zero
Incorrect console calibration
Re-calibrate console
Inconsistent ground speed
reading
Check cabling
Inconsistent flow meter
reading
Replace flow meter
Faulty control valve
Replace control valve
Check using manual increase/decrease flow control
Speed sensor display
is inaccurate, unstable
or zero
Incorrect speed calibration
Re-calibrate console speed
Faulty cable
Test cable as per instructions following
Volume display is
inaccurate, unstable,
zero or not changing
Meter calibration is incorrect Reset meter calibration
Flow meter cable pins are
corroded
Replace flow meter plugs & pins
Flow meter is pointing the
wrong way
Disconnect flow meter and reinstall in the correct
orientation
Faulty cable
Manually test the cable
Flow meter appears
not to be working
Flow meter is seized or
blocked
Remove and clean any foreign materials so the
turbine spins freely
Faulty cable
Test cable as per instructions following
Calibration figure is incorrect
Reset meter calibration
Application rate or
pressure will not alter
Faulty control valve
Test valve manually and replace if required
Control valve has
failed
Faulty cable
Faulty valve
Replace control valve
Temporary solutions:
Remove the motor from the 3 way ball valve and
manually adjust the flow by turning the shaft with a
spanner
Raven Console not
working
No power supply
Check loom connection at the back of the console
Check connection to battery terminals
Check the fuse in the back of the console
With a multi meter, check the voltage potential across
pins 1(-) and 16(+) on the 16 pin plug going into the
console (Should be at least 12v)
If the flow meter fails to give accurate readings, the following actions should be taken:
• Adjust the spraying pressure by putting the flow control switch into manual and using the increase decrease
switch to adjust to the desired pressure as shown on the pressure gauge on the sprayer.
• Drive the sprayer at a constant speed in order to apply the required application volume as determined by
the nozzle selection chart.
• The sprayer should then be operated to empty the tank. Once the sprayer is empty of chemical, partially fill
the tank with fresh water so that test can be performed in order to correct the problem. Repair or replace
the flow meter as soon as possible.
Continued over page
Summary of Contents for Windrow MY18 2500L
Page 4: ......
Page 6: ...Auto Rate Control Raven SCS 450 61 Auto Rate Control Spray Application 62 Engine 63 ...
Page 8: ...Windrow 2500L Operator s Manual MY18 REV 1 2 Chapter 1 Introduction ...
Page 18: ...12 Chapter 4 5 N A Windrow 2500L Operator s Manual MY18 REV 1 ...
Page 26: ...20 Chapter 6 Calibration Windrow 2500L Operator s Manual MY18 REV 1 ...
Page 48: ...42 Chapter 9 Booms Windrow 2500L Operator s Manual MY18 REV 1 ...
Page 56: ...50 Chapter 10 Lubrication Maintenance Windrow 2500L Operator s Manual MY18 REV 1 ...
Page 73: ...Chapter 12 Optional Accessories 67 Windrow 2500L Operator s Manual MY18 REV 1 ...
Page 74: ...www goldacres com au ...