Chapter 11 - Troubleshooting -
53
Windrow 2500L Operator’s Manual MY18 - REV 1
Plumbing
PROBLEM
COMMON CAUSES
COMMON SOLUTION
Boom valves fail to open
Insufficient power.
Check all wiring and connections to ensure
there is 12 volts at the valves.
System pressure greater than
150 PSI.
Reduce the system pressure
Boom valves fail to close
Insufficient power.
Check all wiring and connections to ensure
there is 12 volts at the valves.
Foreign objects blocking plunger
from seating.
Clean the inside of the boom valves.
No water at boom
No Tier valve entered or is at 0 Enter value greater than 0
Summary of Contents for Windrow MY18 2500L