OPERATION
Join the plug-in fitting STN of the medium pressure hose
line
with the quick coupler SKU
Coupling:
r
emove the protective cap from the
SKU
c
ouple the plug-in fitting STN of the
medium pressure hose line with the
quick coupler SKU until you hear it
engage
Carry out LEAK TESTING at the SKU connection!
Decoupling:
h
old the quick coupler SKU by the
knurled gripping surface of the sliding
sleeve, slide it in the direction of the
arrow
t
he plug-in fitting STN is released
c
arry out LEAK TESTING at the SKU
connection!
c
lose the SKU with the protective
cap
Coupling and decoupling must be smooth and manageable without the help of tools.
Connections could become leaky, if they are contaminated or corrupted
Therefore, the connections must regularly be checked for leak-tightness.
Replace
the
product where appropriate.
Keep all connections free from contamination, even small amounts of dirt can cause
connections to leak.
TROUBLESHOOTING
Fault cause
Action
Gas smell
Leaking LPG is
extremely flammable
!
Can cause explosions.
Close the gas supply
!
Do not use any electric switches
!
Do not use a phone in the building
!
Ventilate rooms well
!
Shut down the LPG system
!
Contact a specialised company
!
No gas flow
Open the gas cylinder valve or the shut-off fittings
.
Connect the medium pressure hose
line
.
Turn twist grip to "OPEN" position
.
Still no gas flow:
Send the product to the manufacturer to be checked.
MAINTENANCE
Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.