Caramatic TwoControl
23 / 84
Artikel-Nr. 02 493 50
b
Fault cause
Action
No LED display
Switch in summer or winter operation position
Check the cables (in particular the power supply)
Check the fuse and replace if necessary (ensure that this
is replaced with an identical fuse, see TECHNICAL DATA)
SHUT-DOWN
Close the gas supply and then the shut-off fittings of the connected consumer equipment.
When the LPG system is not in use, all valves must remain closed.
Set the switch to centre position, see OPERATION.
MAINTENANCE
Upon proper ASSEMBLY the product is maintenance-free.
REPLACEMENT
If there is any sign of wear or if the product or parts thereof are damaged, it must be replaced.
When the product has been replaced, observe the steps ASSEMBLY and ELECTRIC
CONNECTION.
TECHNICAL DATA
Ambient temperature
-20 °C to +50 °C
Supply voltage
12 V
Summer mode power consumption
1.5 mA
Winter mode power consumption with Eis-Ex
177 mA
Fuse control panel
Vehicle blade-type fuse F according to
ISO 8820-3
Nominal voltage 32 V
Nominal current 1 A
EXPLOSION PROTECTION DATA
Ignition protection type marking
Supply
U
B
/ U
m
/ I
k
Protection type
Control panel
EX II (3) G [Ex ic Gc] IIA
U
B
=12 V
IP 20
Transmitter for
remote display
EX II 3G Ex ic IIA T3 Gc
U
B
=12 V
IP 20
Eis-Ex regulator
heating
EX II 3G Ex mc IIA T3 Gc
U
B
=12 V
U
m
≤ 16.2
V
I
k
≤ 248
mA
IP 54