Caramatic TwoControl
18 / 84
Artikel-Nr. 02 493
50 b
2.
Wherever possible, designate the installation location for the control panel in a clearly
visible and accessible location and on a flat and smooth surface. To do so, make a
Ø 55mm cutout. Avoid supporting structures in the wall for safety reasons.
3.
Mark four holes for the screws through the front panel.
4.
Guide the 10-pin connector
with connection cable
+
(see ELECTRIC
CONNECTION on pages 7 and 8) into the cutout from behind and connect it to the
10-pin header on the circuit board for the control panel.
5.
Attach the cover socket to the front panel of the control panel, taking care to ensure that
the opening in the cover socket for the 1 A fuse (according to DIN ISO 8820-3) is in the
right place.
6.
Place the cable in the groove in the cover socket and fix it with the cable tie included
(tighten the cable tie and remove the protruding end).
Carry out a functional test (see OPERATION) in order to check that the wiring is correct!