background image

14

DEAR CUSTOMER

Congratulations. You have made a good choice when you decided to buy a GNATUS QUALITY

product comparable to the best products available in the World. This manual is a general presentation of
your product and it will give you important details to help you to solve possible problems.

Please, read it and keep this with you.

Dental chair to accept patient during treatments odontological, with automatic movements, used to

work with – position left and right-handed professionals, it starting by a motor DC with soft start.

Operated by foot control (this component may to be mobile or fixed to base), which many function

in the controls and it work with dental light intensity, seat and backrest movements, return to initial
position, emergency stopping, return to last position, spitting position and two programmable work
positions which are set by the dentist.

It is innovative and modern round-edged design. It curved of the backrest, which improves for

patient with high comfort but produce also approach of the doctor.

The movements are synchronized about the seat and backrest, improving patient high comfort.

When the stopped movement in the backrest descent course, the patient will be in the Trendelemburg
position (legs and pelvis are located in a higher position than thorax and head).

This equipment is accept of the safety component for preventing security device in the foot.
Ergonomically designed steel base, protected by an anti-slip material.
Steel-built structure with a resistant, smooth, high-shine, round-edged coating.
It High-shine smooth epoxy coating, polymerized in stove at 250ºC, with phosphate process resistant

to rust and cleaning products.

The headrest is Bi-articulated anatomic removable with height adjustment, featuring front, rear

and longitudinal movements. Optional cervical rest, which improves high patient comfort.

Round edged fixed armrest, designed to ease the patient access and improve the dentist productivity,

avoiding unnecessary movements and making cleaning and disinfections much easier.

Optional second armrest, with side opening, designed to ease the patient’s access.
Ample seamless upholstery, with lumbar rest, mounted on a rigid structure covered with a high-

resistant polyurethane cover, this coverage use material plastic and seamless upholstery. Removable
Backrest, easy operating the Easy-Fix system, which allows easy removal, cleaning and disinfections.

The seat fixed in the tubular structure, it is easy maintenance and cleaning .
ISO 9001/2000 and ISO 13485/2003 Quality System, assuryng the products are manufactured under

standart procedures.

Products manufactured in agreement with RDC 59 - ANVISA - (Sanitary Surveillance National

Agency) - with guarantees accomplishment hole to the sanitary legislation and according to BPF -
(Good Manufacturing Procedures), requested by Mercosul Sanitary authorities.

In order to comply with directive 93/42/EEC for CE Mark purpose, it is defined that the working life

of metallic structure this product is estimated in 10 years (life-cycle) provided that the end-user follows
the requirements and instructions of this manual.

IMPORTANT:

• This equipment is for dental use use only. It must be operated and utilized by specialized

professional  (certified professional, according to the legislation of the country) and following the
instructions of the manual. The operation of the equipment required, for the professional, the utilization
of correct instruments and it should to be in perfect conditions of the use, and to protect the professional,
the patients and others, in the eventual danger situation.

• This equipment can’t be used in the presence of inflammable anesthetics or products that may

cause explosion.

• After finish life-cycle of the equipment, this equipment is throw way, so it should to be destroyed
in appropriate area (according to the legislation of the country).
•To guarantee the safe functioning of your equipment, use only the assemble configurations (Dental

Chair, Dental and Water Units and Dental Light) supplied by Gnatus authorized Dealers / Technical
Assistance.

PRODUCT DESCRIPTION

Summary of Contents for Cadeira Syncrus GLX

Page 1: ......

Page 2: ...nty of the Equipment 15 General Data 15 Technical Specifications 17 Symbols 18 Dimensions 19 Operation 20 Maintenance 23 Precautions 23 Cleaning 23 Troubleshooting 24 Final Considerations 24 Descripción del Producto 25 Garantía del Equipamiento 26 Datos Generales 26 Especificaciones Técnicas 28 Simbolos 29 Dimensiones 30 Funcionamiento 31 Mantenimiento 34 Precauciones 34 Limpieza 34 Imprevistos 35...

Page 3: ...t productivity avoiding unnecessary movements and making cleaning and disinfections much easier Optional second armrest with side opening designed to ease the patient s access Ample seamless upholstery with lumbar rest mounted on a rigid structure covered with a high resistant polyurethane cover this coverage use material plastic and seamless upholstery Removable Backrest easy operating the Easy F...

Page 4: ...ice Always having in mind the dentist s security we developed the leg bump preventing device When the chair were descending any obstruction below the chair would trigger this device interrupting all functions and preventing further complications see page 20 Electronic board with reversion of voltage The board of electronic circuit allows tHhe connection in any tension of entry 127V or 220V 50 60Hz...

Page 5: ... Swivel armrest with side opening optional 14 Headrest knob 15 Cervical rest optional 01 02 03 04 05 06 07 08 09 10 11 12 14 13 15 List of pieces and circuit scheme Gnatus Company declares that the supply of the circuit scheme list of pieces or any other information that propitiate technical attendance for the user can be request if there is an agreement between the user and Gnatus Company ...

Page 6: ...st be transported and stored with the following observations Carefully should not suffer drop and neither receive impact With the side of the arrow upward With humidity protection not to expose to rains sparkling of water or humidified floor With temperatures from 12ºC to 50ºC With maximum piling up of 04 units for storage DENTAL CHAIR With maximum piling up of 07 units for storage UPHOLSTERY Stan...

Page 7: ...f the dental light high density Activation of the dental light low density It determines the initial position It determines to spitting position last position Lift backrest Lower backrest Lift seat Lower seat It determines the work position 1 If determines the work position 2 B type equipment Turned on position Emergency stop Turned off position Landing in many parts of the equipment indicates the...

Page 8: ...English 19 Dimensions mm TECHNICAL SPECIFICATIONS Content of accessible and non accessible demarcations ...

Page 9: ...per the procedure below Poisitioned in 220V Poisitioned in 127V 1 Desconnect the general key of the chair 2 Remove the finishing cover of the motor 3 Localize the Electronic Board removing the protective cover 4 Put the Jumper 33 accoring to the voltage of the local electric net 127V 220V 5 After doing the operation assembly the covers and turn on again the equipment to the electrical net 33 ATTEN...

Page 10: ...r minutes and the backrest will go up and the set will go down To switch the dental light on press the key 20 or 22 according to desired intensity to change intensity just press the other key To switch it off press the key again After pressing the Inital position 19 key or the Last position Spitting position 18 key any other operation will trigger the Stop and automatically the backrest current po...

Page 11: ...tion below the chair would trigger this function interrupting all movements and preventing further complications Swivel seat The Syncrus GLX chair can swivel thus making cleaning and disinfection easy To move it hold the seat end as shown in picture Headrest To move the headrest loose knob 14 turn it anticlockwise until desired position is reached and fix it turning it clockwise To adjust height j...

Page 12: ...and humidity When moving the chair never get it for the part of the support of the legs lift it for the structure in the area of the seat The plastic parts can t be in contact with most chemical substances used in dentistry treatments i e acids mercury acrylic liquids amalgams etc Whenever off duty turn off the main switch Replacing the fuse With the aid of a screw driver loosen the fuse holder co...

Page 13: ...r the correct maintenance of your equipment Doubts and information GNATUS Call center 55 16 2102 5000 ATTENTION Any other problem that could happen with its equipment should only be repaired by an authorized technician Gnatus The bad use negligence or maintenance not made by technician authorized by the maker will imply in the loss of the warranty Imprevist Problem Probable Cause Solution Chair is...

Page 14: ......

Reviews: