BPS
-40
-100
Output performance
Output voltage max
± 40 V
Output current max
± 100 A
Output power
4 kW
Small signal bandwidth
> 10 kHz (-3dB)
Switching frequency
250 kHz
Voltage mode:
Line regulation
< 0.01 % (supply voltage min-max)
Load regulation
< 0.05 % (output current 0
– max)
Gain accuracy
< 0.02 %
Gain drift vs. time
< 0.01 % (any 8 hour period after 10 min warm up time)
Gain drift vs. temperature
< 0.005 % /ºC (10 ... 40ºC)
Initial offset
< 5 mV (adjustable to 0 mV)
Offset drift vs. time
< 5 mV (any 8 hour period after 10 min warm up time)
Offset drift vs. temperature
< 1 mV /ºC
Output noise voltage
< 0.2Vrms (0.1Hz...200kHz)
Switching ripple voltage
< 500 mVrms differential (>250kHz)
Current Mode:
Line regulation
< 0.01 % (supply voltage min
– max)
Load regulation
< 0.05 % (output voltage 0
– max)
Gain accuracy
< 0.02 %
Gain drift vs. time
< 0.01 % (any 8 hour period after 10 min warm up time)
Gain drift vs. temperature
< 0.005 % /º
C (10 … 40ºC)
Initial offset
< 5 mA (adjustable to 0 mA)
Offset drift vs. time
< 5 mA (any 8 hour period after 10 min warm up time)
Offset drift vs. temperature
< 1 mA /ºC
Output noise current
< 1 mArms (0.1Hz...10kHz)
Switching ripple voltage
< 500 mVrms differential (>250kHz)
Control and monitoring
Local Mode, progamming via front panel:
Voltage mode
-40V to +40V. Setting resolution 10mV
Current mode
-100A to +100A. Setting resolution 10mA
Remote Mode:
Programming, voltage mode
TBD
Programming, current mode
TBD
Signal input impedance
40 kΩ
Fault protection:
Internal overtemperature
(Output shutdown due to)
AC input voltage out of tolerance
Internal voltages out of tolerance
Output crowbar protection for excess returned load energy
Two external interlocks
Features
•
High performance bipolar power supply with ± 40 V, ± 100 A output
•
4-quadrant output operation
•
Operation with wide range of loads
•
Voltage mode and current mode
•
Very low ripple and noise
•
Flux gate current transducer for excellent temperature and long term current stability
•
Ramp response for different loads tuned from front panel
•
Analogue voltage programming of output voltage or current
•
Air cooled, 19 ” rack mountable package (5 U), 55 kg (121 lb)
Summary of Contents for 5203
Page 2: ...Blank Page ...
Page 11: ...9 2 3 11907 0224 0 5203 General Assembly ...
Page 12: ...10 2 4 11907 0233 0 5203 Terminal Block Assembly ...
Page 13: ...11 2 5 17907 0412 0 5203 Mounting Plate ...
Page 24: ...22 9 EXCITATION CURVES AND FIELD UNIFORMITY Excitation Curves for the various pole types ...
Page 25: ...23 Excitation and Field Remanence for the standard pole Type A ...
Page 26: ...24 Near and far vertical field profiles for the standard pole Type A ...
Page 27: ...25 ...
Page 28: ...26 ...
Page 39: ...37 10 TEST DATA ...
Page 41: ...39 13907 0025 1 System Wiring 5203 1x BOP20 50 and PDU ...
Page 42: ...40 13907 0026 1 System Wiring 5203 2x BOP20 50 and PDU ...
Page 43: ...41 1C907 5203 08 Electrical Assembly 5203 and IECO BPS ...
Page 44: ...42 1D907 5203 08 Electrical Wiring 5203 and IECO BPS ...
Page 45: ...43 1C907 5203 09 Electrical Assembly 5203 IECO BPS and 5972 ...
Page 46: ...44 1D907 5203 09 Electrical Wiring 5203 IECO BPS and 5972 ...
Page 48: ...46 16907 0116 1 S1 Cable Current Interlock 5203 BOP20 50 and PDU ...
Page 49: ...47 16907 0116 3 S1 Cable Current Interlock 5203 IECO BPS and 5972 ...
Page 50: ...48 16907 0281 0 Cable Assembly Interlock Pigtail 5972 or IECO BPS ...
Page 51: ...49 11907 0620 0 GMW RC 1920 Equipment Rack ...