Display
TFT 4.3” color display with large view angle
Local mode
Voltage or current mode selected via display
Voltage or current output set by knob
Enable button for activating the output
Remote mode
Remote mode connector on rear panel
Remote mode enabled by logic signal
Voltage or current mode selected by logic signal
Voltage or current output set by analog
programming signal
Tuning
Response for different loads can be
fine-tuned at display
Voltage limit
Absolute max voltage limit set via display
Current limit
Absolute max current limit set via display
System specifications
Input voltage requirements
208V: 180-264VAC 47-63Hz 3-phase Delta, or
400V: 3 x 180-264VAC 47-63Hz L1, L2, L3, N
Selected by switch at rear panel
Input current
typ. 15A/180VAC 12A/230VAC
Power factor
typ. 0.95/230VAC at full load
Efficiency
0.75 at 4kW output power
Inrush current
typ. 60A@230VAC at cold start
Leakage current
< 2mA/240 VAC
Environmental requirements:
Ambient temperature
10 °C to 40 °C
Ambient humidity
30 to 70 % non-condensing
Storage temperature
-20 °C to +85 °C
Cooling
Forced air cooling (front in, rear out)
Removable, washable dust filter with capability
to replace
Unit dimensions:
Mounting
19” rack. Provision for rack slides
Height
221,5 mm (5U, 8.75”)
Width
483 mm (19”)
Depth
740 mm (29.1”)
Weight
55 kg (121 lb)
Bipolar
Power Supply
BPS-40-100
Regulatory
Designed to meet
EN 61010, UL 61010
AC/DC section: UL60950-1, TUV 60950-1 approved
CE marked
Data subject to change without notice. Copyright Oy International Electric Company 2020.
Summary of Contents for 5203
Page 2: ...Blank Page ...
Page 11: ...9 2 3 11907 0224 0 5203 General Assembly ...
Page 12: ...10 2 4 11907 0233 0 5203 Terminal Block Assembly ...
Page 13: ...11 2 5 17907 0412 0 5203 Mounting Plate ...
Page 24: ...22 9 EXCITATION CURVES AND FIELD UNIFORMITY Excitation Curves for the various pole types ...
Page 25: ...23 Excitation and Field Remanence for the standard pole Type A ...
Page 26: ...24 Near and far vertical field profiles for the standard pole Type A ...
Page 27: ...25 ...
Page 28: ...26 ...
Page 39: ...37 10 TEST DATA ...
Page 41: ...39 13907 0025 1 System Wiring 5203 1x BOP20 50 and PDU ...
Page 42: ...40 13907 0026 1 System Wiring 5203 2x BOP20 50 and PDU ...
Page 43: ...41 1C907 5203 08 Electrical Assembly 5203 and IECO BPS ...
Page 44: ...42 1D907 5203 08 Electrical Wiring 5203 and IECO BPS ...
Page 45: ...43 1C907 5203 09 Electrical Assembly 5203 IECO BPS and 5972 ...
Page 46: ...44 1D907 5203 09 Electrical Wiring 5203 IECO BPS and 5972 ...
Page 48: ...46 16907 0116 1 S1 Cable Current Interlock 5203 BOP20 50 and PDU ...
Page 49: ...47 16907 0116 3 S1 Cable Current Interlock 5203 IECO BPS and 5972 ...
Page 50: ...48 16907 0281 0 Cable Assembly Interlock Pigtail 5972 or IECO BPS ...
Page 51: ...49 11907 0620 0 GMW RC 1920 Equipment Rack ...