1 0991 491
EN
-
23.08.2016
1.00
ENG
NGV-EK
V
ALVE
M
ANUAL
I
NSTALLATION
,U
SE AND
M
AINTENANCE
34 / 45
1.7
FLY TIME
Fly time of the lift
V0
Vs/D
Start->Dec
Total
Dec->Stop
OFF
ON
1.7.1
TOTAL
XXX.X S
Total time of the lift travel [s]
1.7.2
START->DEC
XXX.X S
Time between the start of the
lift end the start of the
deceleration phase [s]
1.7.3
DEC->STOP
XXX.X S
Time between the start of the
deceleration phase and the stop
of the lift [s]
- 2 -
ALLARMS
NGV-EK01
2-ALARM
2.1
ALARM 01
00:NO ALARM
Active alarms. Each alarm is identified by a code explained in the
Failure
Chart. Last 8 alarms are stored in memory
…
2.8 ALARM 08
00:NO ALARM
- 3 -
RESET ALLARMS AND FAULT
NGV-EK01
3-AL/FLT RESET
3.1
RESET ?
ESC=NO ENT=YES
Pressing the ENT key on the programmer all the faults and the alarms are
deleted
- 4 -
ADJUSTMENTS
NGV-EK01
4-ADJUSTMENTS
Optimal car motion
Real car motion
A
B
C
4.1
START UP MIN
±XX.X
UPWARD start adjustment (-99 ÷ +99)
A
4.2
SLOW UP MIN
±XX.X
UPWARD levelling speed adjustment (-99 ÷ +99)
B
4.3
HIGH DN MIN
±XX.X
DOWNWARD high speed adjustment (-99 ÷ +99)
C
4.4
SLOW DN MIN
±XX.X
DOWNWARD levelling speed adjustment (-99 ÷ +99)
B
4.5
START UP MAX
±XX.X
UPWARD start adjustment (-99 ÷ +99)
A
4.6
SLOW UP MAX
±XX.X
UPWARD levelling speed adjustment (-99 ÷ +99)
B
4.7
HIGH DN MAX
±XX.X
DOWNWARD high speed adjustment (-99 ÷ +99)
C