Global Mainstream Dynamic Energy Technology Ltd.
- 10 -
User Manual
GHESS 9.8-14.4-TH hybrid system
controller is adopted to manage those battery modules and communicate with hybrid inverter.
C. Energy meter
The 3-phase bi-directional energy meter is for data collection and communication. With the
meter data, the hybrid inverter decides when to charge/ discharge the battery packs.
3 System Installation
3.1 Unpacking and Install Preparations
3.1.1 Before Unpacking
All products are thoroughly tested and inspected before they’re packed and transported.
Although they’re shipped in reliable package, damage during transportation could still occur.
It is important to inspect the shipping package prior to the installation carefully. If any external
damage on the package makes you suspect the device could be damaged or if you find that
the device is damaged after unpacking it, report the damage immediately to your distributor or
the goods forwarder.
If it becomes necessary to return the device, please pack them in the original packages that
they were delivered.
3.1.2 Before Mounting
1. Don’t install the device in direct sunshine. External heating from exposure to the sun may
cause excessive internal heating. This may result in output power de-rating to avoid damage on
internal components
2. The Powervortex 309KTL hybrid inverter weights 55kg and Battery Cabinet weights roughly
200kg. The installation wall must be vertical and the floor must be solid to carry the weight of the
devices
3. Install the GHESS 9.8-14.4-TH in a location where the ambient air temperature is less than 45◦C.
As in the system, the inverter may derate the output power if the ambient air temperature
exceeds 45◦C (The cooler the air temperature, the longer the life expectancy of any electronics
device)
4. Please refer to the Figure 3 to Figure 4 with regards to the installing space for GHESS 9.8-14.4-TH
5. The system should be installed in a location where is inaccessible to children
6. The device is designed for indoor installation (IP20)
7. It is recommended to mount the device at eye level to ensure optimum user comfort
8. Do not install the system on flammable construction materials, in areas close to flammable or
explosive materials