7 Error messages
PC 65 Crimper Operating Instructions – Vers. 1.0
Page 33
of 39
7
Error messages
7.1
Operating pressure is too low
Fig. 38: Operating pressure is too low
7.2
Operating pressure is too high
Fig. 39: Operating pressure is too high
No.
Error
Rectification
1
The crimper does not respond to the foot pedal
and the crimp process does not start
Check the protective cover for proper positioning
Pay attention to the text in the status window.
Compressed air is not connected.
2
Foot pedal opened too early
Letting go of the foot pedal too early causes the crimp
die to open to start position immediately.
Repeat the crimp process.
3
Die does not fully close
The die and crimp contact do not fit together.
The crimp force of the equipment is not adequate.
4
Dies have not been adjusted properly
Disconnect the compressed air supply.
Readjust the die, see 5.3.
5.2.4 Setting the operating pressure
7.3
Decommissioning
Disconnect the equipment from the electrical and compressed air network.