4 Product description
PC 65 Crimper Operating Instructions – Vers. 1.0
Page 17
of 39
Fig. 9: Start up indicator (operating mode 2)
Legend
Item
Description
Meaning
1
Operating mode 2 selection
button
The green triangle indicates the on-state in operating mode 2
2
Opening angle +
The clamping angle of the crimp dies can be increased by pressing this
button
3
Opening angle indicator -
It indicates the set opening angle in % (32% here)
4
Opening angle -
The clamping angle of the crimp dies can be reduced by pressing this but-
ton
5.2.1 Switching on the PC 65 crimper
5.2.2 Switching off the PC 65 crimper
6.2.2 Saving opening angle of the crimp die
6.2.3 Loading the saved opening angle
4.5.6
Operating the foot pedal (operating mode 2)
Fig. 10: Indicator of foot pedal operation (operating mode 2)
Legend
Item
Description
Meaning
1
Cancel button
By pressing this button, the fixing of the contact in the crimp die is can-
celled
2
Counter
It shows the last successful crimp processes (1234 here)
3
Cancel with X
The crimp process can be cancelled/aborted
4
Status window
The status window indicates a fixed contact
5
Status window
Contact fixing has been cancelled
6
Pressure indicator
It shows the operating pressure of the last crimp process (0.58 MPa here)
7
Status window
Last OK crimp
The equipment is ready for the next work process
6.2.8 Cancelling the contact fixing process