29
computer, please check whether you have installed the USB driver correctly. After
installing the USB driver, some computers need to restart and re-plug the USB cable
in order to identify the communication port, or need to update the USB driver in the
Device Manager, or re-open the control software again.
6. Sometimes LED screen may be missing colors (namely no calibration data) during
displaying, please try to repower the screen or click “reset” in “communications” of
the control software for several times, as the following picture:
7.When some individual LED Screen is missing colors, such as the below image, it
may be because the control software cannot read color calibration data, please try to
repower the screen or click “reset” in “communications” of the control software for
several times.
8. If the image of the LED screen is discontinuous, flash or wrong after control
system has been connected, please check whether the address, the parameters and the
port set correctly in the control software, if the LED pixel resolution is out of your
input source resolution.