GLP
German Light Products GmbH
(instruction version 1.33 / from software version 1.53)
37
7
7
Maintaining and Cleaning the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid
residues must not built up on or within the fixture. Otherwise the fixture's light-output will
be significantly reduced or damages can occur. Regular cleaning will not only ensure
the maximum light-output, but will also allow the fixture to function reliable throughout its
life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-
mended, under no circumstances should alcohol or solvents be used!
The inside optical system should be maintained only by authorized persons. Please
contact your local dealer.
7.1 Safety
Regulations
•
Pull out the main plug!
•
Wait min. 20 minutes after the last operation to cool down the fixture.
•
Before you put the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
into operation close the casing, otherwise
your retina can be hurt!
7.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Therefore no
general guidelines can be given. Therefore the intervals given are only
suggestions from our practice experience.
Position
Interval
In this way
Outside optic
weekly
soft cloth and glass cleaning fluid
Color filter/Frost filter
monthly
soft cloth and glass cleaning fluid
Gobos
yearly
vacuum cleaner, airbrush, etc.
Glass gobos
monthly
soft cloth and glass cleaning fluid
Prism
monthly
soft cloth and glass cleaning fluid
Dimmer/Shutter/Iris
yearly
vacuum cleaner, airbrush, etc.
Inside lens
monthly
soft cloth
no
glass cleaning fluid
Fan and air channel
monthly
vacuum cleaner, airbrush, etc.
Reflector
never
Lamp
never
Moveable parts
yearly
suitable fatty oil