Use this function to choose between different display indications. Use the
Up/Down-
keys to select desired function and press
Enter
to confirm or
Mode
to cancel and return to the menu.
D ON
Display On/Off (If you've chosen
off
, the display will go out with-
in 15 seconds after the last menu input. The next key touch will
reactivate the display).
REV
Turn around the display.
Note:
You can also do this by pushing the
Up/Down-
keys at the
same time.
3.9.6 Fixture
Temperature
(TEMP)
TEMP
This function allows you to read out the current temperature of the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
. Press
Enter
to confirm or
Mode
to cancel. Inside temperatures
below 80°C are not critical. 80°C and more lead the lamp being switched
off at a critical point. For a save operation the outside temperature should
not exceed 45°C.
3.9.7 Fan
Control
(FANS)
FANS
By using this function you can choose between 4 types of fan speed
operations. Use the
Up/Down-
keys to select desired function and press
Enter
to confirm or
Mode
to cancel and return to the menu.
HIGH
The cooling fan works continuously at max. speed.
REG
The fan automatically adapts its speed in order to control inside
temperature of the fixture.
LOOF
The fan keeps the adjusted low speed until the temperature
exceeds max. inside temperature, then the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
automatically
switch off
the lamp.
LOHI
The fan keeps the adjusted low speed until the temperature
exceeds max. inside temperature, then the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
automatically
switch from low to high fan speed.
In addition to these settings, you can set the fan speed to minimum via
DMX (Special channel, DMX value 224..229). This will last until a tempera-
ture of 90° is reached
Æ
high speed fan will be activated.