GLP
German Light Products GmbH
(instruction version 1.33 / from software version 1.53)
17
Function
Display
Default Settings
DMX Address
D001
D001
Pan reverse
RPAN
ON
OFF
9
Tilt reverse
RTLT
ON
OFF
9
Automatic lamp on
LAAU
ON
OFF
9
Lamp on via DMX
DLOF
ON
9
OFF
Display
DISP
D ON
9
REV
Cooling fan
FANS
HIGH REG
9
LOOF LOHI
Feedback
FEED
ON
9
OFF
3.9.10 Automatic position control / Feedback
(FEED)
FEED
The
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
is equipped with a automatic position correction
(feedback) for the Pan and Tilt movement. Use the
Up/Down-
keys to select
ON
if you want to enable the feedback function or
Off
if you want to disable
this function. Press
Enter
to confirm or
Mode
to cancel and return to the
menu.
3.9.11 Correction of faults
(EFLG)
(Function available for authorized persons only)
3.10 Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes
after having switched it off (lamp still too hot). The message will appear
on the display if the lamp doesn’t strikes within 20 seconds. The fixture
will store this command and automatically strike the lamp after 5
minutes.
IG E
When striking the lamp, the electronic ballast will examine whether the
lamp is on or not. If the lamp does not strike within 20 seconds, the
igniting sequence is broken off. Now approx. 2 minutes are waited until
a renewed ignition attempt is started automatically. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped and
the display reads "
IG E
" (Ignition error).
LAER
As soon as the lamp ignited correctly, the lamp current is constantly
supervised by the system. If an interruption steps on (covers opened or
lamp damaged), the power is switched off immediately. The display
reads "
LAER
" (lamps error). Please switch off the power supply and
solve the possible problem.
EFLG