3.7  Continuous Color Wheel 

(FCOL)

 

fcol

 

 

This function allows you to control the color wheel continuously. If it is switched 
off, the color wheel is stepping directly from one to another color. 

3.8  Invert Pan Movement 

(RPAN)

 

RPAN

 

 

This function allows you to invert the Pan movement. Use the 

Up/Down-

keys to 

select invert 

On

 or 

Off

. Press 

Enter

 to confirm or 

Mode

 to cancel and return to the 

main menu. 

3.9  Invert Tilt Movement 

(RTLT)

 

RTLT

 

 

This function allows you to invert the Tilt movement. Use the 

Up/Down-

keys to 

select invert 

On

 or 

Off

. Press 

Enter

 to confirm or 

Mode

 to cancel. 

3.10 Special Functions 

(SPEC)

 

SPEC

 

 

This menu allows you to enter further special functions of the 

Y

Y

P

P

O

O

C

C

 

 

5

5

7

7

5

5

 

 

C

C

O

O

L

L

O

O

R

R

.

.

  

In detail they are: 

3.10.1 Manual Drive 

(MANU)

 

MANU

 

 

This function allows you to drive all the fixture functions manually. Select 
the desired function with the 

Up/Down-

keys and confirm with 

Enter

. Now 

choose the desired value with the 

Up/Down-

keys and confirm again with 

Enter 

or cancel and return to the menu with the 

Mode-

key. 

Function 

Value 

Remark 

PAN 

000 - 255 

Pan Position 

TILT 

000 - 255 

Tilt Position 

CYAN 

000 - 255 

Cyan color wheel  

Summary of Contents for YPOC 575 COLOR

Page 1: ...Instruction Manual from software version 1 0 instruction version 1 0 e mail service glp de Internet http www GLP de...

Page 2: ...GLP German Light Production 1 0 2 This side is intentionally unlabelled...

Page 3: ...3 5 Reset RESE 12 3 6 Running time of lamp and unit TIME 12 3 7 Continuous Color Wheel FCOL 13 3 8 Invert Pan Movement RPAN 13 3 9 Invert Tilt Movement RTLT 13 3 10 Special Functions SPEC 13 3 10 1 Ma...

Page 4: ...egulations 21 5 2 Realize the Lamp Change 21 6 Maintenance and Cleaning the Y YP PO OC C 5 57 75 5 C CO OL LO OR R 21 6 1 Safety Regulations 22 6 2 Circumference and Interval rule of thumb 22 6 3 Clea...

Page 5: ...X OUT So ftwa re Upd ate 1 Ground 2 Data 3 Data Mic Sensitivity 6 7 8 9 10 15 6 Software Update connector 7 Microphone Intensity 8 DMX Input 9 DMX Output 10 Fan air inlet outlet 11 Power On Off 12 Mai...

Page 6: ...open the Y YP PO OC C 5 57 75 5 C CO OL LO OR R Please do not touch the bulb of the lamp if you are not absolutely sure it is cold Danger of BURNING 5 Never look directly into the beam of the lamp Yo...

Page 7: ...handles for secondary attachment Pay attention to the regulations of BGV C1 former VBG 70 and DIN VDE 0711 217 The installation should be done by qualified staff only 2 1 1 Clamps There are two major...

Page 8: ...7 75 5 C CO OL LO OR R to mount the unit on a truss each two opposite threads max M10x20 4x M10x20mm 4x Camlock 2 2 Secure the Y YP PO OC C 5 57 75 5 C CO OL LO OR R Regardless of the rigging of the Y...

Page 9: ...rd input output See also printing on the case for the right pin assignment Pin 3 Pin 2 Ground Pin 1 The DMX Addressing starts at the DMX Address 001 2 4 Fuses The Y YP PO OC C 5 57 75 5 C CO OL LO OR...

Page 10: ...OC C 5 57 75 5 C CO OL LO OR R RESE Reset TIME POWR Running time of the fixture no destructible LA1 Running time of the lamp erasable LA2 Running time of the lamp no destructible FCOL Reverse Pan dire...

Page 11: ...LO OR R and wait until the fixture reset has finished RESE is flashing in the display 2 Press the Mode key in order to access the main menu Browse through the menu by pressing the Up Down keys until...

Page 12: ...io function is only working if no DMX is connected This function can work e g on small events or as an emergency program 3 4 Lamp On Off LAMP LAMP Use the Up Down keys to select lamp On or lamp Off Pr...

Page 13: ...you to invert the Tilt movement Use the Up Down keys to select invert On or Off Press Enter to confirm or Mode to cancel 3 10 Special Functions SPEC SPEC This menu allows you to enter further special...

Page 14: ...to confirm or Mode to cancel and return to the menu If you have chosen off you have the possibility to start the lamp either via DMX or direct at the Y YP PO OC C 5 57 75 5 C CO OL LO OR R in the Lamp...

Page 15: ...ction and press Enter to confirm or Mode to cancel and return to the menu D ON Display On Off If you ve chosen off the display will go out within 15 seconds after the last input The next key touch wil...

Page 16: ...nel DMX value 224 229 This will last until a temperature of 90 is reached 3 10 8 Adjustments and Calibrations ADJU ADJU With this function you can adjust and calibrate the positions of the different w...

Page 17: ...ttings DFSE DFSE Press Enter to reset all fixture personalities not the adjusted functions to the default values The display will read ok to indicate that the defaults are set Function Display Default...

Page 18: ...n as the lamp ignited correctly the lamp current is constantly supervised by the system If an interruption steps on covers opened or lamp damaged the power is switched off immediately The display read...

Page 19: ...76 79 4C 4F 30 0 color 4 Pink slow 80 83 50 53 31 6 color 5 Orange slow 84 87 54 57 33 1 color 6 Italian Blue slow 88 91 58 5B 34 7 color 7 Turquoise slow 92 95 5C 5F 36 3 color 8 Jade slow 96 99 60 6...

Page 20: ...0 14 15 0E 0F 5 7 PAN 3 0 16 17 11 11 6 5 3 90 18 19 12 13 7 3 3 180 20 21 14 15 8 0 3 270 22 23 16 17 8 8 PAN 4 0 24 25 18 19 9 6 4 90 26 27 1A 1B 10 4 4 180 28 29 1C 1D 11 2 4 270 30 31 1E 1F 12 TIL...

Page 21: ...wo sidewise lamp screws Attention The glass bulb of the lamp can splinter For that reason remove the lamp with safety gloves or some cloth 5 Put in the new lamp securely with a tight fit into the sock...

Page 22: ...is way Outside optic weekly soft cloth and glass cleaning fluid Color filter monthly soft cloth and glass cleaning fluid Beam shape monthly soft cloth and glass cleaning fluid Dimmer Shutter yearly va...

Page 23: ...white plus 1x CTC 5600k 1x CTC 3300k Beam shape Step less Beam shape Frost filter Motor driven focus from near to far away Zoom Motor driven variable angle of reflected beam from 8 to 22 Shutter Stro...

Page 24: ...ption of Device 5 DIN VDE 0711 217 7 Display 15 DMX 9 DMX Adresse 11 E Error Messages 18 F Fan 15 Fuse 9 I Injury of the retina 6 Invert 13 M Maintenance 21 Measures 23 Mounting 7 P Pan movement 23 Po...

Page 25: ...GLP German Light Production 1 0 25...

Reviews: