Protect the unit against frost.

● 

It is forbidden to make changes to
the tank (welding, brazing, etc.).

● 

Only use original GLORIA spare parts
for repairs.

● 

Important note!

Undue strain

caused by the mode of operation (in-
cluding transport to site where used
and storage when not in use), envi-
ronmental influences (at the site 
where used and where stored when 
not in use), insufficient maintenance 
and care may lead to premature
wear and tear of the unit. For this
reason, always check the unit before
use to make sure that it is in a safe
and operable condition, at least,
however, for outwardly recognisable
signs of damage. To ensure contin-
ued safe operation of the unit, a
technician, preferably from the man-
ufacturer’s service department,
should inspect the unit in the event
of defects affecting safe operation, in
particular, but at a minimum every
12 months.

The national regulations applicable 
at the place of use regarding safety
at work and the national regulations 
applicable to the company must be
complied with.

We reserve the right to make 

technical changes!

CE-statement of conformity for a
module within the meaning of 
Art. 3, section 2 of the directive on
pressurized equipment 97/23/EG

BRILL GLORIA 
Haus- und Gartengeräte GmbH
Därmannsbusch 7
D-58456 Witten

confirms that the water supply unit

Item no. 415....
certificate - no. (Module A1):
07202 1403 Z 0003 / 7 / D001

comply with the directive on pressurized
equipment 97/23/EG and the 
recognized rules of technology .

The procedure for the statement of con-
formity for the module and for the tank
is based on module A1 (Appendix III) of
directive 97/23/EC. 

Notified body, TÜV NORD Systems
GmbH & Co. KG.

Witten, 08.03.07

Hans-Georg Wellerdiek 
(Design Manager)

RZ_976213.qxd  12.03.2007  15:34 Uhr  Seite 10

Summary of Contents for Profiline 415 Series

Page 1: ...leitung 3 6 Instructions for use 7 10 Mode d emploi 11 14 DE GB FR Wasserzuf hrger t Water Supply Unit Cuve d Alimentation d Eau 0045 Ger te f r Industrie und Handwerk RZ_976213 qxd 12 03 2007 13 31 U...

Page 2: ...2 RZ_976213 qxd 12 03 2007 15 34 Uhr Seite 2...

Page 3: ...ersteigen Ein bef lltes Ger t nicht l ngere Zeit starker Sonneneinstrahlung ausset zen Betriebstemperaturen d rfen 50 C nicht berschreiten Ger t so aufbewahren dass es nicht von Kindern benutzt werden...

Page 4: ...lt 13 7 L zul Betriebs berdruck 6 bar zul Betriebstemperatur 0 C bis 50 C Voller Druckwechsel 0 bar bis 6 bar max 5000 Lastwechsel Beh ltermaterial Stahl mit Innenbe schichtung Sicherheitsventil siehe...

Page 5: ...erdruck von 6 bar roter Markie rungsstrich am Manometer im Be h lter erreicht ist berpr fung des Wasserstandes Abb Bei drucklosem Ger t roten Knopf dr cken durch Hochhalten des transparenten Schlauche...

Page 6: ...icherheits bedenklicher M ngel jedoch mindes tens alle 12 Monate haben Sachkun dige am besten der Wartungsdienst des Herstellers zu pr fen ob ein ge fahrloser Betrieb weiterhin m glich ist Die am Betr...

Page 7: ...maximum pressure shown on the pressure gauge must never ex ceed 6 6 bar Do not leave the filled tank in strong sunshine Do not exceed operating temperatures of 50 C Store the unit in a place out of t...

Page 8: ...pe 415 Item no 415 Max capacity 10 L Total tank capacity 13 7 L Max operating pressure 6 bar Max operating temperature 0 C to 50 C Full pressure change 0 bar to 6 bar max 5000 load cycles Tank materia...

Page 9: ...Check of water level Fig When the unit is not under pressure press red button hold upthe trans parent hose The water level in the hose is the same as that in the con tainer and it can be read off the...

Page 10: ...f defects affecting safe operation in particular but at a minimum every 12 months The national regulations applicable at the place of use regarding safety at work and the national regulations applicab...

Page 11: ...d pressurise La pres sion maximale indiqu e sur le manom tre ne doit pas d passer 6 6 bars Ne pas exposer trop longtemps le r servoir de produit de vaporisation en plein soleil Ne pas d passer des tem...

Page 12: ...415 Quantit de remplissage max 10 L Contenu global du r servoir 13 7 L Surpression de service autoris e 6 bars Temp rature de service autoris e 0 C 50 C Changement de pression de 0 bar 6 bar maxi 500...

Page 13: ...nt au moyen du flexible livr avec Actionner la pompe jusqu obtenir une surpression maximale de 6 bars rep re rouge sur le manom tre Contr le du niveau d eau Fig Lorsque la cuve n est pas sous pres sio...

Page 14: ...articulier de manques susceptibles d entraver la s curit et au moins une fois par an des sp cialistes de pr f rence des services d entretien du constructeur doivent v rifier si une utilisation sans da...

Page 15: ...RZ_976213 qxd 12 03 2007 15 34 Uhr Seite 15...

Page 16: ...976 601 00 03 2007 Brill Gloria Haus und Gartenger te GmbH www gloriaindustrialsprayer com RZ_976213 qxd 12 03 2007 13 33 Uhr Seite 5...

Reviews: